DOI 10.1007/s00405-022-07771-3
Relationship between level CPAP titration, anthropometric variables, and drug-induced sleep endoscopy DISE.
Аннотация
INTRODUCTION
Subjects with palatal obstruction alone vs. multilevel obstruction on DISE had better outcomes after palate surgery. We asked ourselves if the therapeutic level positive airway pressure (PAP) titration could predict the level of airway obstruction and its complexity.
PURPOSE: The aim of this study was to identify possible relationships between therapeutic level of positive airway pressure initial titration and levels of collapse in drug-induced sleep endoscopy (DISE). A secondary objective was to establish the relationship the other variables and DISE.
METHODS
We analyzed retrospective clinical histories between March 2020 to March 2022 of 37 patients with polysomnography or cardiorespiratory polygraphy studies and PAP initial titration who were taken to drug-induced sleep endoscopy. Sleep study data, anthropometric variables, and patterns of airway collapse during DISE were analyzed with PAP initial titration levels.
RESULTS
Most of the patients with complex collapse had concentric velum collapse (p < 0.006). A significant association was found between the apnea-hypopnea index (AHI) and oropharyngeal collapse; (p < 0.0030) and finally we demonstrated relationship between neck circumference and gender with epiglottis collapse (p < 0.046), (p < 0.037), respectively.
CONCLUSIONS
Our findings show a strong relationship between that complex collapses and concentric velum collapse; patients with greater oropharyngeal collapse have a higher mean AHI. Patients without epiglottic collapse have a higher mean neck circumference. An association between mean pressure initial titration and complex collapse could not be established.