MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0000000000001886

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2023

von Willebrand Factor and Angiopoietin-2 are Sensitive Biomarkers of Pulsatility in Continuous-Flow Ventricular Assist Device Patients.

Nguyen Khanh T, Hecking Jana, Berg Ian C, Kannappan Ramaswamy, Donoghue Leslie, Ismail Esraa, Cheng Xuanhong, Giridharan Guruprasad A, Sethu Palaniappan

СтатьяПоддержка правительства СШАПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

Nonsurgical bleeding occurs in a significant proportion of patients implanted with continuous-flow ventricular assist devices (CF-VADs) and is associated with nonphysiologic flow with diminished pulsatility. An in vitro vascular pulse perfusion model seeded with adult human aortic endothelial cells (HAECs) was used to identify biomarkers sensitive to changes in pulsatility. Diminished pulsatility resulted in an ~45% decrease in von Willebrand factor (vWF) levels from 9.80 to 5.32 ng/ml (n = 5, p < 0.05) and a threefold increase in angiopoietin-2 (ANGPT-2) levels from 775.29 to 2471.93 pg/ml (n = 5, p < 0.05) in cultured HAECs. These changes are in agreement with evaluation of patient blood samples obtained pre-CF-VAD implant and 30-day postimplant: a decrease in plasma vWF level by 50% from ~45.59 to ~22.49 μg/ml (n = 15, p < 0.01) and a 64% increase in plasma ANGPT-2 level from 7,073 to 11,615 pg/ml (n = 8, p < 0.05). This study identified vWF and ANGPT-2 as highly sensitive to changes in pulsatility, in addition to interleukin-6 (IL-6), IL-8, and tumor necrosis-α (TNF-α). These biomarkers may help determine the optimal level of pulsatility and help identify patients at high risk of nonsurgical bleeding.

Для цитирования: Nguyen Khanh T, Hecking Jana, Berg Ian C, Kannappan Ramaswamy, Donoghue Leslie, Ismail Esraa, Cheng Xuanhong, Giridharan Guruprasad A, Sethu Palaniappan. von Willebrand Factor and Angiopoietin-2 are Sensitive Biomarkers of Pulsatility in Continuous-Flow Ventricular Assist Device Patients.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2023. DOI: 10.1097/mat.0000000000001886.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.