MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s40262-021-01034-w

Медицинская библиотека · Clinical pharmacokinetics · 2021

Thoroughly Validated Bayesian Estimator and Limited Sampling Strategy for Dose Individualization of Ganciclovir and Valganciclovir in Pediatric Transplant Recipients.

Franck Bénédicte, Autmizguine Julie, Åsberg Anders, Théorêt Yves, Marquet Pierre, Ovetchkine Philippe, Woillard Jean-Baptiste

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVE

Given a high pharmacokinetic inter-individual variability and a low exposure target achievement, ganciclovir (GCV) therapeutic drug monitoring is sometimes used in children. We aimed to develop and validate Bayesian estimators based on limited sampling strategies for the estimation of GCV area under the concentration-time curve from 0 to 24 h in pediatric transplant recipients treated with valganciclovir (VGCV) or GCV.

METHODS

Solid organ transplant or stem-cell transplant recipients who received GCV or VGCV and had available GCV concentrations per standard of care were retrospectively included in this study for pharmacokinetic modeling and development of Bayesian estimators using the iterative two-stage Bayesian method. Validation datasets included additional child recipients of a solid organ transplant or stem-cell transplant, and child recipients of a kidney or liver transplant enrolled in a previous study. Various combinations of three or two sampling times, applicable in clinical practice, were assessed based on the relative mean bias, standard deviation, and the root mean square error in a development dataset and three independent validation datasets.

RESULTS

In the development dataset, the mean bias/standard deviation/root mean square error for the 1 h/2 h/3 h and 1 h/3 h limited sampling strategies were - 1.4%/9.3%/9.1% and - 3.5%/12.2%/12.3%, respectively for GCV, while for VGCV, the mean bias/standard deviation/root mean square error for the 1 h/2 h/6 h and 1 h/6 h limited sampling strategies were 0.7%/13.5%/13.3% and - 0.1%/12.1%/11.8%, respectively. In the independent validation datasets, seven (13%) and five (14%) children would have had misclassifications of their exposure using these Bayesian estimators and limited sampling strategies for VGCV and GCV, respectively.

CONCLUSIONS

Three plasma samples collected at 1 h/2 h/3 h and 1 h/2 h/6 h post-dose for GCV and VGCV respectively, are sufficient to accurately determine GCV area under the concentration-time curve from 0 to 24 h for pharmacokinetic-enhanced therapeutic drug monitoring.

Для цитирования: Franck Bénédicte, Autmizguine Julie, Åsberg Anders, Théorêt Yves, Marquet Pierre, Ovetchkine Philippe, Woillard Jean-Baptiste. Thoroughly Validated Bayesian Estimator and Limited Sampling Strategy for Dose Individualization of Ganciclovir and Valganciclovir in Pediatric Transplant Recipients.. Clinical pharmacokinetics. 2021. DOI: 10.1007/s40262-021-01034-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.