MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1248/bpb.b20-00400

Медицинская библиотека · Biological & pharmaceutical bulletin · 2020

Development of a Diagnostic Screening Strategy for Niemann-Pick Diseases Based on Simultaneous Liquid Chromatography-Tandem Mass Spectrometry Analyses of N-Palmitoyl-O-phosphocholine-serine and Sphingosylphosphorylcholine.

Iwahori Anna, Maekawa Masamitsu, Narita Aya, Kato Akie, Sato Toshihiro, Ogura Jiro, Sato Yu, Kikuchi Masafumi, Noguchi Atsuko, Higaki Katsumi, Okuyama Torayuki, Takahashi Tsutomu, Eto Yoshikatsu, Mano Nariyasu

СтатьяПеревод пока не подготовлен

Аннотация

Early diagnosis of Niemann-Pick diseases (NPDs) is important for better prognosis of such diseases. N-Palmitoyl-O-phosphocholine-serine (PPCS) is a new NPD biomarker possessing high sensitivity, and with its combination with sphingosylphosphocholine (SPC) it may be possible to distinguish NPD-C from NPD-A/B. In this study, a rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method (method 1) and a validated LC-MS/MS analysis (method 2) of PPCS and SPC were developed, and we have proposed a diagnostic screening strategy for NPDs using a combination of serum PPCS and SPC concentrations. Nexera and API 5000 were used as LC-MS/MS systems. C18 columns with lengths of 10 and 50 mm were used for method 1 and 2, respectively. 2H3-Labeled PPCS and nor-SPC were used as internal standards. Selective reaction monitoring in positive-ion mode was used for MS/MS. Run times of 1.2 and 8 min were set for methods 1 and 2, respectively. In both methods 1 and 2, two analytes showed high linearity in the range of 1-4000 ng/mL. Method 2 provided high accuracy and precision in method validation. Serum concentrations of both analytes were significantly higher in NPD-C patients than those of healthy subjects in both methods. Serum PPCS correlated between methods 1 and 2; however, it was different in the case of SPC. The serum PPCS/SPC ratio was different in healthy subjects, NPD-C, and NPD-A/B. These results suggest that using a combination of the two LC-MS/MS analytical methods for PPCS and SPC is useful for diagnostic screening of NPDs.

Для цитирования: Iwahori Anna, Maekawa Masamitsu, Narita Aya, Kato Akie, Sato Toshihiro, Ogura Jiro, Sato Yu, Kikuchi Masafumi, Noguchi Atsuko, Higaki Katsumi, Okuyama Torayuki, Takahashi Tsutomu, Eto Yoshikatsu, Mano Nariyasu. Development of a Diagnostic Screening Strategy for Niemann-Pick Diseases Based on Simultaneous Liquid Chromatography-Tandem Mass Spectrometry Analyses of N-Palmitoyl-O-phosphocholine-serine and Sphingosylphosphorylcholine.. Biological & pharmaceutical bulletin. 2020. DOI: 10.1248/bpb.b20-00400.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.