MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aor.14727

Медицинская библиотека · Artificial organs · 2024

Successful explantation of children from the Berlin Heart EXCOR® ventricular assist device: A systematic review.

Mikulski Matthew F, Iyer Swati, Well Andrew, Mery Carlos M, Owens W Richard, Glass Lauren D, Castleberry Chesney D, Fraser Charles D

Систематический обзорСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The Berlin Heart EXCOR® (BHE) can bridge children with severe heart failure to transplantation, but some are successfully weaned and spared transplantation. This study seeks to identify characteristics of children amenable to successful explantation with BHE support.

METHODS

Preferred Reporting Items for Systematic reviews and Meta-Analyses 2020 guidelines were used. Five databases were screened for original, English articles measuring BHE support in patients <18 years old based on title and abstract. Exclusion criteria were applied: full-text availability, <10 total pediatric BHE patients, zero successful explantations from BHE, nonprimary literature, adult and pediatric results that could not be separated, and studies with overlapping patient information. Studies were analyzed with descriptive statistics.

RESULTS

From 41 857 potential studies, 14 were analyzed with data from 58 hospitals on four continents from 1990 to 2020. There were 984 BHE patients. The most common diagnosis was dilated cardiomyopathy (n = 318, 32.3%), followed by congenital heart disease (n = 249, 25.3%). There were 85 (8.6%) children explanted with favorable outcomes. The underlying diagnosis was known in 44 (51.8%) cases: 14 (8.4%) of 166 cardiomyopathies, 17 (48.6%) of 35 myocarditis, and 12 (16.7%) of 72 with congenital heart disease were explanted. When the type of support was known, the rate of LVAD patients explanted was 21.3% (n = 19/89) and 2.4% (n = 1/42) of BiVAD patients were explanted.

CONCLUSION

Explantation from BHE is not uncommon at 8.6%, but significant variation exists in the explantation data reported. Myocarditis and LVAD support may be populations suitable for weaning. Standardization of reporting measures and prospective registries may help identify patients suitable for this alternative to transplant and help develop weaning protocols.

Для цитирования: Mikulski Matthew F, Iyer Swati, Well Andrew, Mery Carlos M, Owens W Richard, Glass Lauren D, Castleberry Chesney D, Fraser Charles D. Successful explantation of children from the Berlin Heart EXCOR® ventricular assist device: A systematic review.. Artificial organs. 2024. DOI: 10.1111/aor.14727.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.