Аннотация

BACKGROUND

Intraoperative ultrasonography (IOUS) is considered the standard for the identification of liver metastases. Use of lipid-stabilized perfluorobutane microbubbles as an ultrasound contrast agent may improve this. The value of contrast-enhanced IOUS (CE-IOUS) in enumerating colorectal liver metastases was studied here.

METHODS

CE-IOUS was performed in consecutive resections for colorectal liver metastases in 2007-2010. All patients underwent preoperative computed tomography. Magnetic resonance imaging was not carried out routinely. Conventional intraoperative examination including IOUS, and CE-IOUS with peripherally injected contrast were performed. The histopathological findings and 6-month follow-up images were used as the reference standard.

RESULTS

The study group of 102 patients had a total of 315 lesions identified on preoperative imaging (2·4 lesions per operation; 129 operations). Conventional intraoperative examination including IOUS identified 350 lesions (2·7 per operation). CE-IOUS identified 370 lesions (2·9 per operation). The sensitivity, specificity and accuracy of CE-IOUS were 97·1, 59·1 and 93·2 per cent respectively. The CE-IOUS findings altered the surgical plan in 19 operations (14·7 per cent).

CONCLUSION

CE-IOUS provided additional information to that obtained using contemporary preoperative imaging and conventional intraoperative examinations.

Для цитирования: Takahashi M, Hasegawa K, Arita J, Hata S, Aoki T, Sakamoto Y, Sugawara Y, Kokudo N. Contrast-enhanced intraoperative ultrasonography using perfluorobutane microbubbles for the enumeration of colorectal liver metastases.. The British journal of surgery. 2012. DOI: 10.1002/bjs.8844.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.