MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7518/hxkq.2025.2025077

Медицинская библиотека · Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology · 2025

[Comparative study on the accuracy of extraoral scanning versus intraoral scanning in digital impressions for implant restoration in edentulous jaws].

Yang Yongtao, Li Xin, Shang Xiangyi, Shan Shenyao, Li Wenbo, Qin Qingzhao, Wang Yong, Zhao Yijiao

СтатьяСравнительное исследованиеАннотация на английскомПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate the accuracy of a self-developed extraoral scanning system based on four-camera stereophotogrammetric technology in the acquisition of three-dimensional positional information on dental implants and conduct a comparative study involving an intraoral scanning system.

METHODS

With the use of an in vitro edentulous jaw model with implants, extraoral (experimental group) and intraoral (control group) scanning systems were employed to obtain STL (Standard Tessellation Language) datasets containing three-dimensional morphological and positional information on scan bodies. In addition, a dental model scanner was used to obtain reference data. The three-dimensional morphological, linear, and angular deviations between groups and reference data were analyzed using Geomagic Wrap 2021 software to compare trueness and precision.

RESULTS

The extraoral scanning system demonstrated superior trueness in three-dimensional morphological, linear, and angular deviations compared with the intraoral scanning system, with statistically significant differences (P<0.001). The extraoral scanning system also showed a higher precision in three-dimensional morphological deviation (P<0.001). As the number of implants increased, the extraoral scanning system exhibited increased three-dimensional morphological and linear deviations (P<0.001) but maintained a stable angular deviation. The intraoral scanning system displayed significant increases in three-dimensional morphological, linear, and angular deviations with the increase in the number of implants (P<0.05).

CONCLUSIONS

The stereophotogrammetry-based extraoral scanning system outperforms intraoral scanning system in terms of the accuracy for multi-unit implant positioning and provides a novel approach for attaining a fully digital workflow for implant rehabilitation in edentulous jaws.

Для цитирования: Yang Yongtao, Li Xin, Shang Xiangyi, Shan Shenyao, Li Wenbo, Qin Qingzhao, Wang Yong, Zhao Yijiao. [Comparative study on the accuracy of extraoral scanning versus intraoral scanning in digital impressions for implant restoration in edentulous jaws].. Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology. 2025. DOI: 10.7518/hxkq.2025.2025077.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.