MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cmpb.2022.107002

Медицинская библиотека · Computer methods and programs in biomedicine · 2022

Development of predictive statistical shape models for paediatric lower limb bones.

Shi Beichen, Barzan Martina, Nasseri Azadeh, Carty Christopher P, Lloyd David G, Davico Giorgio, Maharaj Jayishni N, Diamond Laura E, Saxby David J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

Accurate representation of bone shape is important for subject-specific musculoskeletal models as it may influence modelling of joint kinematics, kinetics, and muscle dynamics. Statistical shape modelling is a method to estimate bone shape from minimal information, such as anatomical landmarks, and to avoid the time and cost associated with reconstructing bone shapes from comprehensive medical imaging. Statistical shape models (SSM) of lower limb bones have been developed and validated for adult populations but are not applicable to paediatric populations. This study aimed to develop SSM for paediatric lower limb bones and evaluate their reconstruction accuracy using sparse anatomical landmarks.

METHODS

We created three-dimensional models of 56 femurs, 29 pelves, 56 tibias, 56 fibulas, and 56 patellae through segmentation of magnetic resonance images taken from 29 typically developing children (15 females; 13 ± 3.5 years). The SSM for femur, pelvis, tibia, fibula, patella, haunch (i.e., combined femur and pelvis), and shank (i.e., combined tibia and fibula) were generated from manual segmentation of comprehensive magnetic resonance images to describe the shape variance of the cohort. We implemented a leave-one-out cross-validation method wherein SSM were used to reconstruct novel bones (i.e., those not included in SSM generation) using full- (i.e., full segmentation) and sparse- (i.e., anatomical landmarks) input, and then compared these reconstructions against bones segmented from magnetic resonance imaging. Reconstruction performance was evaluated using root mean squared errors (RMSE, mm), Jaccard index (0-1), Dice similarity coefficient (DSC) (0-1), and Hausdorff distance (mm). All results reported in this abstract are mean ± standard deviation.

RESULTS

Femurs, pelves, tibias, fibulas, and patellae reconstructed via SSM using full-input had RMSE between 0.89 ± 0.10 mm (patella) and 1.98 ± 0.38 mm (pelvis), Jaccard indices between 0.77 ± 0.03 (pelvis) and 0.90 ± 0.02 (tibia), DSC between 0.87 ± 0.02 (pelvis) and 0.95 ± 0.01 (tibia), and Hausdorff distances between 2.45 ± 0.57 mm (patella) and 9.01 ± 2.36 mm (pelvis). Reconstruction using sparse-input had RMSE ranging from 1.33 ± 0.61 mm (patella) to 3.60 ± 1.05 mm (pelvis), Jaccard indices ranging from 0.59 ± 0.10 (pelvis) to 0.83 ± 0.03 (tibia), DSC ranging from 0.74 ± 0.08 (pelvis) to 0.90 ± 0.02 (tibia), and Hausdorff distances ranging from 3.21 ± 1.19 mm (patella) to 12.85 ± 3.24 mm (pelvis).

CONCLUSIONS

The SSM of paediatric lower limb bones showed reconstruction accuracy consistent with previously developed SSM and outperformed adult-based SSM when used to reconstruct paediatric bones.

Для цитирования: Shi Beichen, Barzan Martina, Nasseri Azadeh, Carty Christopher P, Lloyd David G, Davico Giorgio, Maharaj Jayishni N, Diamond Laura E, Saxby David J. Development of predictive statistical shape models for paediatric lower limb bones.. Computer methods and programs in biomedicine. 2022. DOI: 10.1016/j.cmpb.2022.107002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.