MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00068-022-01973-4

Медицинская библиотека · European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2022

Prehospital extremity tourniquet placements-performance evaluation of non-EMS placement of a lifesaving device.

Mokhtari Ava K, Mikdad Sarah, Luckhurst Casey, Hwabejire John, Fawley Jason, Parks Jonathan J, Mendoza April E, Kaafarani Haytham M A, Velmahos George C, Bloemers Frank W, Saillant Noelle N

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The education of civilians and first responders in prehospital tourniquet (PT) utilization has spread rapidly. We aimed to describe trends in emergency medical services (EMS) and non-EMS PT utilization, and their ability to identify proper clinical indications and to appropriately apply tourniquets in the field.

METHODS

A retrospective cohort study was conducted to evaluate all adult patients with PTs who presented at two Level I trauma centers between January 2015 and December 2019. Data were collected via an electronic patient query tool and cross-referenced with institutional Trauma Registries. Medically trained abstractors determined if PTs were clinically indicated (limb amputation, vascular hard signs, injury requiring hemostasis procedure, or significant documented blood loss). PTs were further designated as appropriately or inappropriately applied (based on tourniquet location, venous tourniquet, greater than 2-h ischemic time). Descriptive statistics and univariate analyses were performed.

RESULTS

146 patients met inclusion criteria. The incidence of yearly PT placements increased between 2015 and 2019, with an increase in placement by non-EMS personnel (police, firefighter, bystander, and patient). Improvised PTs were frequently utilized by bystanders and patients, whereas first responders had high rates of commercial tourniquet use. A high proportion of tourniquets were placed without indication (72/146, 49%); however, the proportion of PTs placed without a proper indication across applier groups was not statistically different (p = 0.99). Rates of inappropriately applied PTs ranged from 21 to 46% across all groups applying PTs.

CONCLUSIONS

PT placement was increasingly performed by non-EMS personnel. Present data indicate that non-EMS persons applied PTs at a similar performance level of those applied by EMS. Study LevelLevel III.

Для цитирования: Mokhtari Ava K, Mikdad Sarah, Luckhurst Casey, Hwabejire John, Fawley Jason, Parks Jonathan J, Mendoza April E, Kaafarani Haytham M A, Velmahos George C, Bloemers Frank W, Saillant Noelle N. Prehospital extremity tourniquet placements-performance evaluation of non-EMS placement of a lifesaving device.. European journal of trauma and emergency surgery : official publication of the European Trauma Society. 2022. DOI: 10.1007/s00068-022-01973-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.