MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.ajkd.2016.10.023

Медицинская библиотека · American journal of kidney diseases : the official journal of the National Kidney Foundation · 2017

Bioimpedance and Fluid Status in Children and Adolescents Treated With Dialysis.

Milani Gregorio P, Groothoff Jaap W, Vianello Federica A, Fossali Emilio F, Paglialonga Fabio, Edefonti Alberto, Agostoni Carlo, Consonni Dario, van Harskamp Dewi, van Goudoever Johannes B, Schierbeek Henk, Oosterveld Michiel J S

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Assessment of hydration status in patients with chronic kidney failure treated by dialysis is crucial for clinical management decisions. Dilution techniques are considered the gold standard for measurement of body fluid volumes, but they are unfit for day-to-day care. Multifrequency bioimpedance has been shown to be of help in clinical practice in adults and its use in children and adolescents has been advocated. We investigated whether application of multifrequency bioimpedance is appropriate for total-body water (TBW) and extracellular water (ECW) measurement in children and adolescents on dialysis therapy.

STUDY

DESIGN

A study of diagnostic test accuracy.

SETTING &

PARTICIPANTS

16 young dialysis patients (before a hemodialysis session or after peritoneal dialysis treatment) from the Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy, and the Emma Children's Hospital-Academic Medical Center, Amsterdam, the Netherlands.

INDEX TEST: TBW and ECW volumes assessed by multifrequency bioimpedance.

REFERENCE TESTS: TBW and ECW volumes measured by deuterium and bromide dilution, respectively.

RESULTS

Mean TBW volumes determined by multifrequency bioimpedance and deuterium dilution were 19.2±8.7 (SD) and 19.3±8.3L, respectively; Bland-Altman analysis showed a mean bias between the 2 methods of -0.09 (95% limits of agreement, -2.1 to 1.9) L. Mean ECW volumes were 8.9±4.0 and 8.3±3.3L measured by multifrequency bioimpedance and bromide dilution, respectively; mean bias between the 2 ECW measurements was +0.6 (95% limits of agreement, -2.3 to 3.5).

LIMITATIONS: Participants ingested the deuterated water at home without direct supervision by investigators, small number of patients, repeated measurements in individual patients were not performed.

CONCLUSIONS

Multifrequency bioimpedance measurements were unbiased but imprecise in comparison to dilution techniques. We conclude that multifrequency bioimpedance measurements cannot precisely estimate TBW and ECW in children receiving dialysis.

Для цитирования: Milani Gregorio P, Groothoff Jaap W, Vianello Federica A, Fossali Emilio F, Paglialonga Fabio, Edefonti Alberto, Agostoni Carlo, Consonni Dario, van Harskamp Dewi, van Goudoever Johannes B, Schierbeek Henk, Oosterveld Michiel J S. Bioimpedance and Fluid Status in Children and Adolescents Treated With Dialysis.. American journal of kidney diseases : the official journal of the National Kidney Foundation. 2017. DOI: 10.1053/j.ajkd.2016.10.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.