MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-018-4135-1

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2018

Factors associated with lamina cribrosa displacement after trabeculectomy measured by optical coherence tomography in advanced primary open-angle glaucoma.

Esfandiari Hamed, Efatizadeh Ali, Hassanpour Kiana, Doozandeh Azadeh, Yaseri Mehdi, Loewen Nils A

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the relationship of lamina cribrosa displacement to corneal biomechanical properties and visual function after mitomycin C-augmented trabeculectomy.

METHOD: Eighty-one primary open-angle eyes were imaged before and after trabeculectomy using an enhanced depth spectral domain optical coherence tomography (SDOCT). Corneal biomechanical properties were measured with the ocular response analyzer before the surgery. The anterior lamina cribrosa (LC) was marked at several points in each of the six radial scans to evaluate LC displacement in response to intraocular pressure (IOP) reduction. A Humphrey visual field test (HVF) was performed before the surgery as well as 3 and 6 months, postoperatively.

RESULTS

Factors associated with a deeper baseline anterior lamina cribrosa depth (ALD) were cup-disc ratio (P = 0.04), baseline IOP (P = 0.01), corneal hysteresis (P = 0.001), and corneal resistance factor (P = 0.001). After the surgery, the position of LC became more anterior (negative), posterior (positive), or remained unchanged. The mean LC displacement was - 42 μm (P = 0.001) and was positively correlated with the magnitude of IOP reduction (regression coefficient = 0.251, P = 0.02) and negatively correlated with age (regression coefficient = - 0.224, P = 0.04) as well as baseline cup-disk ratio (Regression coefficient = - 0.212, P = 0.05). Eyes with a larger negative LC displacement were more likely to experience an HVF improvement of more than a 3 dB gain in mean deviation (P = 0.002).

CONCLUSION

A larger IOP reduction and younger age was correlated with a larger negative LC displacement and improving HVF. The correlation between lower SDOCT cup-disc ratio and postoperative negative LC displacement was borderline (P = 0.05). Corneal biomechanics did not predict LC displacement.

Для цитирования: Esfandiari Hamed, Efatizadeh Ali, Hassanpour Kiana, Doozandeh Azadeh, Yaseri Mehdi, Loewen Nils A. Factors associated with lamina cribrosa displacement after trabeculectomy measured by optical coherence tomography in advanced primary open-angle glaucoma.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2018. DOI: 10.1007/s00417-018-4135-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.