MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2016.01.134

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2016

Diagnostic Accuracy and Safety of CT-Guided Percutaneous Transthoracic Needle Biopsies: 14-Gauge versus 22-Gauge Needles.

Ocak Sebahat, Duplaquet Fabrice, Jamart Jacques, Pirard Lionel, Weynand Birgit, Delos Monique, Eucher Philippe, Rondelet Benoît, Dupont Michael, Delaunois Luc, Sibille Yves, Dahlqvist Caroline

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the diagnostic accuracy and safety of a 14-gauge core needle versus a 22-gauge fine needle in the evaluation of thoracic lesions by CT-guided percutaneous transthoracic needle biopsy (TTNB).

MATERIALS AND

METHODS

Medical charts of all patients who underwent CT-guided percutaneous transthoracic core-needle biopsies (CNBs) with a 14-gauge Spirotome device (99 patients, 102 procedures) and fine-needle biopsies (FNBs) with a 22-gauge Rotex needle (92 patients, 102 procedures) between 2007 and 2013 at a single academic institution were retrospectively reviewed. Variables that could influence diagnostic accuracy and safety were collected.

RESULTS

The overall and cancer-specific diagnostic accuracy rates were 90% and 94%, respectively, with CNB, versus 82% and 89% with FNB. Precise cancer type/subtype was provided by 97% of CNBs versus 65% of FNBs (P < .001). In patients with lung cancer considered for targeted therapy, biomarker analyses were feasible in 80% of CNBs versus 0% of FNBs (P < .001). The rate of pneumothorax was significantly higher with CNB versus FNB (31% vs 19%; P = .004), but chest tube insertion rates were similar (10% vs 11%, respectively). Major bleeding complications occurred in 1% of CNBs versus 2% of FNBs and were associated with one death in the CNB group.

CONCLUSIONS

Percutaneous transthoracic CNB with a 14-gauge Spirotome needle provided better characterization of cancer lesions and allowed biomarker analyses without a significant increase in major procedural complications.

Для цитирования: Ocak Sebahat, Duplaquet Fabrice, Jamart Jacques, Pirard Lionel, Weynand Birgit, Delos Monique, Eucher Philippe, Rondelet Benoît, Dupont Michael, Delaunois Luc, Sibille Yves, Dahlqvist Caroline. Diagnostic Accuracy and Safety of CT-Guided Percutaneous Transthoracic Needle Biopsies: 14-Gauge versus 22-Gauge Needles.. Journal of vascular and interventional radiology : JVIR. 2016. DOI: 10.1016/j.jvir.2016.01.134.