Медицинская библиотека · Journal of clinical monitoring and computing · 2025

Does the thoracic fluid content reflect lung water and cardiac preload?

Rosalba Daniela, Shi Rui, Bruscagnin Chiara, Lai Christopher, Fouque Gaëlle, Hagry Julien, Vaschetto Rosanna, Teboul Jean-Louis, Monnet Xavier

СтатьяПеревод пока не подготовлен

Аннотация

Whether the thoracic fluid content (TFC) estimated by bioimpedance actually reflects the thoracic water content and tracks its changes has not been tested yet. We compared TFC changes induced by volume expansion with those of well-established markers of cardiac preload including the global end-diastolic volume indexed (GEDVI) estimated by transpulmonary thermodilution (TPTD) and central venous pressure (CVP). We assessed the relationship between TFC and extravascular lung water indexed (EVLWI) estimated by TPTD in patients with acute respiratory distress syndrome (ARDS). In 42 patients with a TPTD device (PiCCO2), we measured GEDVI, EVLWI and CVP before and after a 500-mL fluid bolus (Fluid group). In 23 different patients with ARDS, we measured the day-to-day changes in TFC and EVLWI (ARDS group). In the Fluid group (42 measurements), TFC increased significantly during fluid infusion. There was no correlation between the fluid-induced changes in GEDVI or CVP and the fluid-induced changes in TFC (p = 0.71 and p = 0.09, respectively). In the ARDS group, 124 measurements were performed, representing 101 changes between timepoints. There was no correlation between the percent changes in GEDVI, EVLWI, the sum of GEDVI + EVLWI and the percent changes in TFC (p = 0.52, 0.40 and 0.55, respectively). Considering all 208 measurements performed, absolute values of EVLWI were correlated with absolute values of TFC (r = 0.21, p = 0.04). There was no correlation between the absolute values of GEDVI and the sum of GEDVI + EVLWI and those of TFC (p = 0.33 and 0.39, respectively). Still considering all measurements performed, the percentage of error of cardiac index measured by bioreactance compared to TPTD was 131%. In critically ill patients, TFC measured by bioimpedance does not follow the changes induced by a fluid bolus of well-known markers of cardiac preload. It also does not follow the changes in EVLWI observed in patients with ARDS. While absolute values of TFC are weakly correlated with those of EVLWI, it is determined neither by GEDVI, nor by the sum of both.

Для цитирования: Rosalba Daniela, Shi Rui, Bruscagnin Chiara, Lai Christopher, Fouque Gaëlle, Hagry Julien, Vaschetto Rosanna, Teboul Jean-Louis, Monnet Xavier. Does the thoracic fluid content reflect lung water and cardiac preload?. Journal of clinical monitoring and computing. 2025. DOI: 10.1007/s10877-025-01335-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.