MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iae.0000000000004201

Медицинская библиотека · Retina (Philadelphia, Pa.) · 2024

COMPLEX MACULAR HOLE CLOSURE BY TEMPORAL INTERNAL LIMITING MEMBRANE FLAP WITHOUT ENDOTAMPONADE.

Szeto Simon K H, Yu Amy H Y, Tsang Chi Wai, Mohamed Shaheeda, Chen Li Jia, Lai Timothy Y Y

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the safety, efficacy, and imaging features of a novel surgical technique without endotamponade in repairing complex macular hole (MH).

METHODS

Retrospective review of consecutive cases with complex MH underwent pars plana vitrectomy with temporal internal limiting membrane flap, which was stabilized using perfluorocarbon liquid and viscoelastics. At the conclusion of surgery, perfluorocarbon liquid was removed, and no endotamponade agent would be used. Complex MH was defined as a basal linear diameter of ≥400 µm and/or associated with high myopia. Visual acuity, pattern of MH closure on optical coherence tomography, formation of epiretinal membrane, and operative complications were reported.

RESULTS

Twenty-four eyes were included, and the mean basal linear diameter was 988.3 µm. MH closure was achieved in 24 (100%), of which, 8 (33%) achieved type 1A closure. The mean postoperative logarithm of the minimum angle of resolution visual acuity improved from 0.93 at baseline to 0.74, 0.51, 0.55, and 0.52 at 1-month, 3-month, 6-month, and last follow-up, respectively. Foveal gliosis was observed in 3 eyes (12.5%), and 10 (41.7%) developed nasal epiretinal membrane. One eye developed vitreous hemorrhage, which resolved spontaneously.

CONCLUSION

This novel surgical technique that requires no endotamponade is effective in achieving complex MH closure. A substantial proportion of patients developed epiretinal membrane, and its clinical significance requires further investigation.

Для цитирования: Szeto Simon K H, Yu Amy H Y, Tsang Chi Wai, Mohamed Shaheeda, Chen Li Jia, Lai Timothy Y Y. COMPLEX MACULAR HOLE CLOSURE BY TEMPORAL INTERNAL LIMITING MEMBRANE FLAP WITHOUT ENDOTAMPONADE.. Retina (Philadelphia, Pa.). 2024. DOI: 10.1097/iae.0000000000004201.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.