DOI 10.1158/1078-0432.ccr-13-1153
Imaging the norepinephrine transporter in neuroblastoma: a comparison of [18F]-MFBG and 123I-MIBG.
Аннотация
PURPOSE: The norepinephrine transporter (NET) is a critical regulator of catecholamine uptake in normal physiology and is expressed in neuroendocrine tumors like neuroblastoma. Although the norepinephrine analog, meta-iodobenzylguanidine (MIBG), is an established substrate for NET, (123)I/(131)I-MIBG has several clinical limitations for diagnostic imaging. In the current studies, we evaluated meta-[(18)F]-fluorobenzylguanidine ([(18)F]-MFBG) and compared it with (123)I-MIBG for imaging NET-expressing neuroblastomas.
EXPERIMENTAL
DESIGN
NET expression levels in neuroblastoma cell lines were determined by Western blot and (123)I-MIBG uptake assays. Five neuroblastoma cell lines and two xenografts (SK-N-BE(2)C and LAN1) expressing different levels of NET were used for comparative in vitro and in vivo uptake studies.
RESULTS
The uptake of [(18)F]-MFBG in cells was specific and proportional to the expression level of NET. Although [(18)F]-MFBG had a 3-fold lower affinity for NET and an approximately 2-fold lower cell uptake in vitro compared with that of (123)I-MIBG, the in vivo imaging and tissue radioactivity concentration measurements demonstrated higher [(18)F]-MFBG xenograft uptake and tumor-to-normal organ ratios at 1 and 4 hours after injection. A comparison of 4 hours [(18)F]-MFBG PET (positron emission tomography) imaging with 24 hours (123)I-MIBG SPECT (single-photon emission computed tomography) imaging showed an approximately 3-fold higher tumor uptake of [(18)F]-MFBG, but slightly lower tumor-to-background ratios in mice.
CONCLUSIONS
[(18)F]-MFBG is a promising radiopharmaceutical for specifically imaging NET-expressing neuroblastomas, with fast pharmacokinetics and whole-body clearance. [(18)F]-MFBG PET imaging shows higher sensitivity, better detection of small lesions with low NET expression, allows same day scintigraphy with a shorter image acquisition time, and has the potential for lower patient radiation exposure compared with (131)I/(123)I-MIBG.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.