MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcct.2024.09.011

Медицинская библиотека · Journal of cardiovascular computed tomography · 2024

Reproducibility of myocardial extracellular volume quantification using dual-energy computed tomography in patients with cardiac amyloidosis.

Kadoya Yoshito, Omaygenc Mehmet Onur, Chow Benjamin, Small Gary R

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Quantifying myocardial extracellular volume (ECV) using computed tomography (CT) has been shown to be useful in the evaluation of cardiac amyloidosis. However, the reproducibility of CT measurements for myocardial ECV, is not well-established in patients with proven cardiac amyloidosis.

METHODS

This prospective single-center study enrolled cardiac amyloidosis patients to undergo dual-energy CT for myocardial fibrosis assessment. Delayed imaging at 7 and 8 ​min post-contrast and independent evaluations by two blinded cardiologists were performed for ECV quantification using 16-segment (ECVglobal) and septal sampling (ECVseptal). Inter- and intraobserver variability and test-retest reliability were measured using Spearman's rank correlation, Bland-Altman analysis, and intraclass correlation coefficients (ICC).

RESULTS

Among the 24 participants (median age ​= ​78, 67 ​% male), CT ECVglobal and ECVseptal showed median values of 53.6 ​% and 49.1 ​% at 7 ​min, and 53.3 ​% and 50.1 ​% at 8 ​min, respectively. Inter- and intraobserver variability and test-retest reliability for CT ECVglobal (ICC ​= ​0.798, 0.912, and 0.894, respectively) and ECVseptal (ICC ​= ​0.791, 0.898, and 0.852, respectively) indicated good reproducibility, with no evidence of systemic bias between observers or scans.

CONCLUSIONS

Dual-energy CT-derived ECV measurements demonstrated good reproducibility in patients with proven cardiac amyloidosis, suggesting potential utility as a repeatable imaging biomarker for this disease.

Для цитирования: Kadoya Yoshito, Omaygenc Mehmet Onur, Chow Benjamin, Small Gary R. Reproducibility of myocardial extracellular volume quantification using dual-energy computed tomography in patients with cardiac amyloidosis.. Journal of cardiovascular computed tomography. 2024. DOI: 10.1016/j.jcct.2024.09.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.