Reference values for the water load test in healthy school children and adolescents.

Peralta-Palmezano F J, Escobar-Serna D P, Peralta-Palmezano J J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND STUDY AIM: The water load test (WLT) is an easy and cheap tool, useful in evaluating gastric accommodation and visceral hypersensitivity. This test can be used in diagnosing functional gastrointestinal disorders, like functional dyspepsia. Our main aim was to propose reference values for the WLT. Our secondary aim was to correlate the water volume drunk with the students' gender, age, and anthropometric measures.

PATIENTS AND

METHODS

We performed the WLT in students aged 8 to 17 years. Students drank water ad libitum for 3 minutes or until pain, satiety or vomiting occurred. We correlated anthropometric variables with water volumes drunk. Upper and lower limit for the maximum tolerated volume were calculated as the 5th and 95th percentile. Pain and nausea were recorded before and after the test.

RESULTS

We evaluated 99 students, with a median age (inter quartile range) of 11 years 10-13 years) and 55.6 % were girls. Median water volume drank was 380 ml (190-540 ml). Boys (523 ml, interquartile range : 275-760 ml) drank more water than girls (380 ml, interquartile range : 190-570 ml) (p = 0.016). There was a significant correlation between water volume drank and students´ age, weight, height, and body mass index. Of the students that completed the WLT, 22.2 % had nausea and 30.3 % had mild abdominal pain after the test.

CONCLUSIONS

We proposed reference values for the WLT in children aged 8 to 17 years. Adverse effects are minimal, it is safe to perform, and well tolerated.

Для цитирования: Peralta-Palmezano F J, Escobar-Serna D P, Peralta-Palmezano J J. Reference values for the water load test in healthy school children and adolescents.. Acta gastro-enterologica Belgica. 2021. DOI: 10.51821/84.2.299.