MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2020.02.007

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2020

Characterisation of internal, refractive, and corneal astigmatism in a UK university student population.

Nagra Manbir, Dashrathi Rucha, Senthan Eileen, Jahan Thasnia, Campbell Peter

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: There is a clear benefit in defining internal (IA) and corneal astigmatic error (CA) prior to surgical and other refractive interventions, such as orthokeratology, to minimise risk of unsatisfactory refractive outcomes. Such data would also be of relevance to broader areas of ophthalmic care such as spectacle dispensing and other types of rigid lens fitting. This study offers a detailed characterisation of astigmatic error in a group of university students and specifically investigates compensation of corneal astigmatism by the eye's internal optics.

METHODS

For 176 young-adult participants, objective measurements of refractive error were obtained using the open-view Grand Seiko WAM-5500 autorefractor; corneal curvature and axial length were measured using the Aladdin biometer. Clinical measurements of corneal and refractive astigmatism were converted into vector components J0 and J45; followed by an assessment of corneal astigmatism compensation.

RESULTS

Mean total refractive astigmatism (RA), CA, and IA were 0.24 ± 0.32D, 0.46 ± 0.27D and -0.21 ± 0.25D respectively for J0 and -0.05 ± 0.20D, 0.01 ± 0.16D, and -0.06 ± 0.18D for J45. Significant linear correlations were noted between RA, CA, and IA for both J0 and J45 (P < 0.01). A significant linear regression was also noted between axial length and J45 RA and IA, but not CA. Levels of full compensation were low, 7% and 9% for J0 and J45 respectively, however, a complete absence of compensation was also uncommon particularly for J45 (2%).

CONCLUSIONS

In general, partial compensation for corneal astigmatism by the eye's internal optics is noted, but it is unclear whether this is an active compensatory mechanism. Further, larger scale, studies would be required to characterise differences in corneal astigmatic compensation with respect to ethnicity.

Для цитирования: Nagra Manbir, Dashrathi Rucha, Senthan Eileen, Jahan Thasnia, Campbell Peter. Characterisation of internal, refractive, and corneal astigmatism in a UK university student population.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2020. DOI: 10.1016/j.clae.2020.02.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.