MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4155/bio-2020-0020

Медицинская библиотека · Bioanalysis · 2020

LC-MS/MS method for the quantification of SUVN-G3031, a novel H3 receptor inverse agonist for narcolepsy treatment.

Nirogi Ramakrishna, Ajjala Devender Reddy, Prakash Padala Naga Surya, Kalaikadhiban Ilayaraja, Rayapati Lakshmi Prasanna, Chunduru Prathyusha, Shinde Anil

СтатьяПеревод пока не подготовлен

Аннотация

Background

A LC-MS/MS method was validated for the quantification of SUVN-G3031, a novel H3 receptor inverse agonist in clinical development for the treatment of patients with narcolepsy, with and without cataplexy. Methodology: SUVN-G3031 was extracted from plasma following acetonitrile protein precipitation, separated by Ultra HPLC and quantified using positive ESI-MS/MS.

Results

The method was linear across the range of 0.1-100 ng ml-1 in plasma. Results for intra and inter-day accuracy were from 99.8 to 104% and precision (%CV) was ≤10.6%.

Conclusion

The method was applied to a first-in-human study in healthy volunteers. The method is precise, accurate and highly selective for the quantification of SUVN-G3031 in human plasma.

Для цитирования: Nirogi Ramakrishna, Ajjala Devender Reddy, Prakash Padala Naga Surya, Kalaikadhiban Ilayaraja, Rayapati Lakshmi Prasanna, Chunduru Prathyusha, Shinde Anil. LC-MS/MS method for the quantification of SUVN-G3031, a novel H3 receptor inverse agonist for narcolepsy treatment.. Bioanalysis. 2020. DOI: 10.4155/bio-2020-0020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.