MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mrm.70251

Медицинская библиотека · Magnetic resonance in medicine · 2026

Motion- and Field-Robust Mesoscopic Whole-Brain T 2 * $$ {T}_2^{\ast } $$ -Weighted Imaging at 7 and 11.7 T Using Servo Navigation.

Serger Matthias, Stirnberg Rüdiger, Ehses Philipp, Riedel Malte, Ulrich Thomas, Le Ster Caroline, Mauconduit Franck, Gras Vincent, Amadon Alexis, Vignaud Alexandre, Chu Son, Gunamony Shajan, Zaitsev Maxim, Boulant Nicolas, Pruessmann Klaas P, Stoecker Tony

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To mitigate artifacts related to motion and field changes in high-resolution T 2 * $$ {T}_2^{\ast } $$ -weighted human brain imaging using servo navigation at ultra-high fields up to 11.7 T.

METHODS

MR-based servo navigators were integrated into a segmented 3D-EPI sequence to allow for prospective correction of involuntary head motion and first-order shim changes. Seven subjects were scanned with whole-brain protocols at 0.3 mm isotropic resolution with and without correction at 7 and 11.7 T. Validation was performed on detailed brain vasculature in scans with involuntary motion.

RESULTS

Blurring of small veins was reduced by servo navigation for all subjects and across field strengths. In case of involuntary large motion, the method preserved image quality, while uncorrected motion led to severe artifacts. In case of microscopic motion, reduced blurring and shading in the frontal lobe demonstrate the additional benefit of prospective field drift correction.

CONCLUSION

Servo-navigated segmented 3D-EPI improves 0.3 mm isotropic whole-brain T 2 * $$ {T}_2^{\ast } $$ -weighted imaging under realistic motion and field changes within 5.5 to 11 min scan time at 11.7 and 7 T.

Для цитирования: Serger Matthias, Stirnberg Rüdiger, Ehses Philipp, Riedel Malte, Ulrich Thomas, Le Ster Caroline, Mauconduit Franck, Gras Vincent, Amadon Alexis, Vignaud Alexandre, Chu Son, Gunamony Shajan, Zaitsev Maxim, Boulant Nicolas, Pruessmann Klaas P, Stoecker Tony. Motion- and Field-Robust Mesoscopic Whole-Brain T 2 * $$ {T}_2^{\ast } $$ -Weighted Imaging at 7 and 11.7 T Using Servo Navigation.. Magnetic resonance in medicine. 2026. DOI: 10.1002/mrm.70251.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.