MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/opo.12599

Медицинская библиотека · Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2019

From suppression to stereoacuity: a composite binocular function score for clinical research.

Webber Ann L, Wood Joanne M, Thompson Benjamin, Birch Eileen E

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: This study aimed to validate a binocular function score that is based on common clinical measures of visual function, providing a more complete analysis of binocular outcomes, against laboratory-based dichoptic tests of threshold stereoacuity and depth of suppression.

METHODS

Scores on a composite binocular function (BF) score derived from clinical stereoacuity measures (Randot Preschool Stereoacuity Test and Randot Butterfly) and the Worth 4 Dot test were determined in adults (n = 20; age 24.8 ± 7.2 years) and children (N = 77; age 8.3 ± 1.7 years) with abnormal binocular vision from strabismus or amblyopia. Adults had threshold stereoacuity measured with a novel, computerised dichoptic psychophysical test of stereopsis. Depth of suppression (dichoptic eye chart inter-ocular contrast balance test) was determined in both adults and children.

RESULTS

Clinical Randot stereoacuity was measurable in 50% of adult and 61% of child participants. Threshold stereoacuity was measurable in 65% of the adult participants. The presence of suppression or simultaneous perception (flat fusion or diplopia) was measurable in all participants, enabling assignment of a BF score to all participants in both groups. In adults, the BF score was highly correlated with the psychophysical threshold stereoacuity measure (ρ = 0.71; p < 0.001). In both adults and children, there was also a high correlation between the BF score and inter-ocular contrast balance (adult ρ = 0.90; child ρ = 0.86; p < 0.001).

CONCLUSIONS

The composite BF score is a convenient and valid scale of binocularity that can be used to extend the stereoacuity measure in cohorts where nil stereoacuity is common and thus could be considered as an outcome measure in clinical trials.

Для цитирования: Webber Ann L, Wood Joanne M, Thompson Benjamin, Birch Eileen E. From suppression to stereoacuity: a composite binocular function score for clinical research.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2019. DOI: 10.1111/opo.12599.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.