MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Surgical technology international · 2019

Near-Infrared Indocyanine Green-Enhanced Fluorescence and Evaluation of the Bowel Microperfusion During Robotic Colorectal Surgery: a Retrospective Original Paper.

Mangano Alberto, Fernandes Eduardo, Gheza Federico, Bustos Roberto, Chen Liaohai Leo, Masrur Mario, Giulianotti Pier Cristoforo

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Leakage of the anastomosis after colorectal surgery is a severe complication, and one of the most important causes is poor vascular supply. However, a microvascular deficit is often not detectable during surgery under white light. Near-infrared indocyanine green (ICG)-enhanced fluorescence may be useful for assessing microvascular deficits and conceivably preventing anastomotic leakage.

OBJECTIVES

This paper presents a preliminary retrospective case series on robotic colorectal surgery. The aim is to evaluate the feasibility, safety and role of near-infrared ICG-enhanced ?uorescence for the intraoperative assessment of peri-anastomotic tissue vascular perfusion.

MATERIALS AND

METHODS

From among more than 164 robotic colorectal cases performed, we retrospectively analyzed 28 that were all performed by the same surgeon (PCG) using near-infrared ICG-enhanced fluorescence technology: 16 left colectomies (57.1%), 8 rectal resections (28.6%), 3 right colectomies (10.8%) and 1 pancolectomy (3.6%).

RESULTS

The rates of conversion, intraoperative complications, dye allergic reaction and mortality were all 0%. In two cases (7.1%)-1 left and 1 right colectomy-the level of the anastomosis was changed intraoperatively after ICG showed ischemic tissues. Despite the application of ICG, one anastomotic leak (after left colectomy for a chronic recurrent sigmoid diverticulitis with pericolic abscess) was observed.

CONCLUSIONS

ICG technology may help to determine when to intraoperatively change the anastomotic level to a safer location. In our case series, ICG results led to a change in the level of the anastomosis in 7.1% of the cases. Despite the use of ICG, we observed one leak. This may have been related to vascularization-independent causes (e.g., infection in this case) or may reflect a need for better standardization of this ICG technology. In particular, we need a way to objectively assess the ICG signal and the related risk of leakage. More randomized, prospective, well-powered trials are needed to unveil the full potential of this innovative surgical technology.

Для цитирования: Mangano Alberto, Fernandes Eduardo, Gheza Federico, Bustos Roberto, Chen Liaohai Leo, Masrur Mario, Giulianotti Pier Cristoforo. Near-Infrared Indocyanine Green-Enhanced Fluorescence and Evaluation of the Bowel Microperfusion During Robotic Colorectal Surgery: a Retrospective Original Paper.. Surgical technology international. 2019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.