MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/08941939.2013.826311

Медицинская библиотека · Journal of investigative surgery : the official journal of the Academy of Surgical Research · 2013

Rapid placement of bicaval dual-lumen catheter in a swine model of venovenous ECMO.

Hayes Don, Yates Andrew R, Duffy Victoria L, Tobias Joseph D, Mansour Heidi M, Olshove Vincent F, Preston Thomas J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Venovenous (VV) extracorporeal membrane oxygenation (ECMO) applied through a single site with a bicaval dual-lumen (BCDL) catheter is a growing method of treatment of acute respiratory failure, thus animal models for research purposes are needed. We describe a rapid technique for the placement of the BCDL catheter for single-site VV ECMO in swine.

DESIGN

Prior to the application of single-site VV ECMO model with common crossbred piglets, BCDL catheters were placed using anatomical landmarks. Transthoracic echocardiography (TTE) with color Doppler was used to determine catheter placement. Final determination of catheter placement was confirmed by necropsy. Arterial blood gas and hemodynamic parameters were recorded at baseline and then hourly. The values are mean ± SD.

RESULTS

Using anatomical landmarks by positioning the BCDL catheter tip approximately 6.5 cm distal to the tip of the manubrium, cannulation was easily accomplished in five piglets with no positional adjustments of the catheter required. Cannula placement was confirmed with both TTE color Doppler and necropsy. Respiratory support was achieved with baseline and hourly measurements of pH 7.45 ± 0.03, 7.44 ± 0.07, 7.46 ± 0.05, 7.47 ± 0.06 (p = NS); PO2 86 ± 30 mmHg, 98 ± 30 mmHg, 94 ± 40 mmHg, and 79 ± 30 mmHg (p = NS); and PCO2 43 ± 3 mmHg, 44 ± 8 mmHg, 38 ± 5 mmHg, and 40 ± 4 mmHg (p = NS).

CONCLUSIONS

Using anatomical landmarks for the placement of the BCDL catheter was rapid and effective in a swine model of VV ECMO, resulting in improved time efficiency for research.

Для цитирования: Hayes Don, Yates Andrew R, Duffy Victoria L, Tobias Joseph D, Mansour Heidi M, Olshove Vincent F, Preston Thomas J. Rapid placement of bicaval dual-lumen catheter in a swine model of venovenous ECMO.. Journal of investigative surgery : the official journal of the Academy of Surgical Research. 2013. DOI: 10.3109/08941939.2013.826311.