Comparison of ventricular synchrony in children with left bundle branch area pacing and right ventricular septal pacing.
Аннотация
OBJECTIVE
This study aimed to determine the ideal pacing site in children by comparing the postoperative ventricular synchrony in children with left bundle branch area pacing and those with right ventricular septal pacing.
METHODS
This retrospective study included children with complete atrioventricular block who underwent permanent pacemaker implantation from March 2019 to August 2021. Patients were grouped according to their ventricular pacing site, the left bundle branch area pacing group and the right ventricular septal pacing group. Two-dimensional speckle tracking echocardiography was used to evaluate the ventricular synchrony.
RESULTS
Forty-eight children (median age, 2.7 years; interquartile range, 1.7-4.6 years) were included. The paced QRS duration in the left bundle branch area pacing group was significantly narrower than that in the right ventricular septal pacing group (100.2 ± 9.3 versus 115.4 ± 15.1 ms, p = 0.001). The median follow-up duration was 1.5 years (interquartile range, 1-2 years). At the last follow-up, the average capture threshold of the ventricular electrode in the left bundle branch area pacing group was lower than that in the right ventricular septal pacing group (0.79 ± 0.18 versus 1.20 ± 0.56 V, p = 0.008). The left ventricular intraventricular synchrony parameters in the left bundle branch area pacing group were better than those in the right ventricular septal pacing group (e.g. standard deviation of the time to peak longitudinal strain, 37.4 ± 4.3 versus 46.6 ± 8.2 ms, p = 0.000). The average interventricular mechanical delay time in the left bundle branch area pacing group was significantly shorter than that in the right ventricular septal pacing group (36.4 ± 14.2 versus 52.5 ± 22.7 ms, p = 0.016).
CONCLUSION
Compared with right ventricular septal pacing, left bundle branch area pacing in children produces a narrower QRS duration and better pacing and ventricular synchrony parameters postoperatively.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.