m+Medelevator.RU
← Поиск публикаций
Pacing and clinical electrophysiology : PACE · 2023

Left ventricular pacing in the treatment of pediatric cardiac dysfunction caused by idiopathic complete left bundle branch block.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Li Xiaomei, Li Jinghao, Jin Yongqiang, Jiang He, Cui Jian, Zhang Yi, Li Meiting, Zhou Huiming

Аннотация

OBJECTIVE: This study aimed to investigate the feasibility and effectiveness of transthoracic epicardial dual-chamber pacemaker implantation in the treatment of cardiac dysfunction caused by idiopathic complete left bundle branch block (CLBBB) in children.

METHODS: Nine children diagnosed with cardiac dysfunction due to idiopathic CLBBB were included in this study. All patients underwent transthoracic epicardial dual-chamber pacemaker implantation. Cardiac function was evaluated using echocardiography during the follow-up. Additionally, intraventricular synchronization parameters were assessed using two-dimensional speckle tracking echocardiography (STE).

RESULTS: Nine children (mean age, 3.0 ± 2.6 years) were included in this study. The median follow-up duration was 2 (interquartile range, 1-3) years. The cardiac function of all patients recovered to normal levels within 1 year postoperatively. The postoperative QRS duration on electrocardiography (142 ± 21 ms) was significantly shorter than that at baseline (106 ± 12 ms) (p < .05). Cardiac dyssynchrony in patients who manifested preoperatively achieved complete correction after pacemaker implantation. The comparison of preoperative and postoperative (last follow-up visit) synchronization parameters were as follows: longitudinal standard deviation of the time to peak strain, 99.0 ± 41.9 versus 36.8 ± 5.0 ms (p = .004); delay time of peak longitudinal strain, 252.2 ± 131.4 versus 35.0 ± 22.9 ms (p = .002); and longitudinal systolic dyssynchrony index, 2.8 ± 0.8% versus 1.0 ± 0.3% (p = .001), respectively.

CONCLUSION: Transthoracic epicardial dual-chamber pacemaker implantation (with left atrial sensing and left ventricular single-site pacing) can be used for the treatment of cardiac dysfunction caused by idiopathic CLBBB in children.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты