Outcomes of a 320-degree intrastromal corneal ring segment implantation for keratoconus: Results of a 6-month follow-up.
Аннотация
IMPORTANCE
This study shows that a newer long-arc length intrastromal corneal ring segment is efficient and safe for keratoconus treatment.
BACKGROUND
To evaluate visual, tomographic results and complications of a 320-degree intrastromal corneal ring segment implantation with the femtosecond laser for keratoconus treatment.
DESIGN
A prospective, nonrandomized, and interventional study.
PARTICIPANTS
A total of 34 eyes of 31 patients diagnosed with keratoconus were enrolled.
METHODS
Patients were divided into two groups based on the strategy used for 320-degree intrastromal corneal ring segment thickness selection. In one group, this selection was based on spherical equivalent (SE group) and in the other on the mean asphericity (Q group). The uncorrected and corrected distance visual acuities, spherical equivalent, K1, K2, Km, Kmax, and mean asphericity (Q) on corneal tomography were evaluated preoperatively and at 3 and 6 months postoperatively. For astigmatism improvement, we analyzed the corneal tomographic vectorial astigmatism change preoperatively and at 6 months postoperatively. The mean follow-up period was 6.63 ± 0.96 months.
RESULTS
The mean uncorrected distance visual acuity and corrected distance visual acuity improved with a significant spherical equivalent improvement (p < 0.05), with no differences between the 320-degree intrastromal corneal ring segment groups. All corneal tomographic parameters improved significantly (p < 0.05) between the preoperative and postoperative intervals, with a significant better performance when we used spherical equivalent for the 320-degree intrastromal corneal ring segment thickness selection. Finally, the mean vectorial corneal tomographic astigmatism significantly improved after 6 months, again with no differences between groups.
CONCLUSION
This study suggests that implanting a 320-degree intrastromal corneal ring segment is a safe and effective procedure for treating patients with keratoconus. It also suggests that for thickness selection spherical equivalent is the better strategy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.