DOI 10.5935/0004-2749.20190003
Effect of accelerated corneal crosslinking on ocular response analyzer waveform-derived parameters in progressive keratoconus.
Аннотация
PURPOSE: To evaluate the effect of accelerated corneal crosslinking on corneal biomechanics with an ocular response analyzer in patients with progressive keratoconus.
METHODS
In this retrospective study, 50 eyes of 45 patients with progressive keratoconus who underwent accelerated corneal crosslinking were evaluated with ocular response analyzer waveform parameters before and one year after corneal crosslinking. Paired two-tailed Student's t-test was performed to compare the parameters before vs. after corneal crosslinking.
RESULTS
Mean patient age was 17.6 ± 3.6 (range 9-25) years. A significant increase was observed in p1 area, p2 area, h2, and dive2 values. No significant difference in corneal hysteresis, corneal resistance factor, or other waveform-derived parameters was observed at one year postoperatively.
CONCLUSION
For estimating the effect of accelerated corneal crosslinking on corneal biomechanics, parameters such as p1 area, p2 area, h2, and dive2 are more sensitive than corneal hysteresis and corneal resistance factor. These results may help us to find out which corneal crosslinking method is most effective for stiffening the cornea.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.