MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000001709

Медицинская библиотека · Cornea · 2018

Clinical Outcomes After Implantation of 320°-Arc Length Intrastromal Corneal Ring Segments in Keratoconus.

Torquetti Leonardo, Cunha Priscila, Luz Allan, Kwitko Sérgio, Carrion Márcio, Rocha Guilherme, Signorelli Armando, Coscarelli Sandro, Ferrara Guilherme, Bicalho Frederico, Neves Renato, Ferrara Paulo

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the clinical outcomes after implantation of a new 320°-arc length Ferrara intrastromal corneal ring segment (320-ICRS) in eyes of patients with keratoconus.

METHODS

A multicentric nonrandomized study was conducted in which a new 320-ICRS was placed in 138 eyes of 130 patients with keratoconus. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), keratometry, corneal volume, asphericity, lines of vision gain/loss, and vectorial analysis were assessed preoperatively and at the final follow-up visit after the procedure.

RESULTS

The mean follow-up time was 6.2 ± 3.3 (SD) months (range 3-12 months). Mean UDVA improved from 20/250 to 20/60. Mean CDVA improved from 20/100 to 20/40. Mean Q improved from -1.12 ± 0.49 preoperatively to -0.28 ± 0.51 postoperatively (P < 0.001). Mean corneal volume increased from 56.2 ± 4.28 mm preoperatively to 57.6 ± 4.74 postoperatively (P < 0.001). Mean Km reduced from 53.3 ± 5.5 D preoperatively to 47.8 ± 4.6 D postoperatively (P < 0.001). The change in UDVA, CDVA, and topographic astigmatism was statistically significant (P < 0.0001).

CONCLUSIONS

The 320-ICRS can efficiently and safely improve visual acuity in keratoconus, modifying the corneal shape to a more physiologic, aspheric shape.

Для цитирования: Torquetti Leonardo, Cunha Priscila, Luz Allan, Kwitko Sérgio, Carrion Márcio, Rocha Guilherme, Signorelli Armando, Coscarelli Sandro, Ferrara Guilherme, Bicalho Frederico, Neves Renato, Ferrara Paulo. Clinical Outcomes After Implantation of 320°-Arc Length Intrastromal Corneal Ring Segments in Keratoconus.. Cornea. 2018. DOI: 10.1097/ico.0000000000001709.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.