Current eye research · 2018
Optical Performance of the Cornea One Year Following Keratoconus Treatment with Corneal Collagen Cross-Linking.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Uysal Betul Seher, Sarac Ozge, Yaman Derya, Akcay Emine, Cagil Nurullah
Аннотация
PURPOSE: The purpose of the study is to assess changes in optical performance of the cornea in patients with keratoconus following treatment with corneal collagen crosslinking (CXL).
MATERIALS AND METHODS: One hundred and eleven eyes of 111 consecutive keratoconus patients with 12-month follow-up after CXL were included. The changes in the visual acuity, manifest refractive errors, and corneal topographic parameters were evaluated. Sirius dual-scanning corneal tomography was used to determine the effectiveness of CXL on each patient's total corneal optical quality; preoperative and 12-month postoperative measurements were analyzed over a 4-mm stimulated pupil and were compared with regards to higher order corneal aberrations (total amount of higher order aberrations [HOAs], vertical coma, horizontal coma, vertical trefoil, oblique trefoil, and spherical aberration), vertical and horizontal modulation transfer function (MTF), and Strehl ratio of point spread function (PSF).
RESULTS: At 12 months, there was a significant improvement in mean uncorrected visual acuity (UCVA) (P < 0.001), best corrected visual acuity (BCVA) (P < 0.001), spherical equivalent refraction (P = 0.007), and manifest astigmatic refraction (P < 0.001). The corneal topographic measurements revealed a significant decrease in the mean simulated keratometry-1, simulated keratometry -2, and maximum keratometry compared with the baseline measurements (P < 0.001, for all). In addition, there were significant improvements in mean root mean square error values for corneal total HOA (P < 0.001), vertical coma (P < 0.001), and vertical trefoil (P = 0.008) following CXL. Mean MTF and Strehl ratio did not change after CXL (P > 0.05). The improvement in UCVA significantly correlated with the changes in vertical trefoil (r = -0.191, P = 0.044), and the improvement in BCVA and the changes in manifest astigmatic correction were also significantly correlated (r = -0.247, P = 0.009) 12 months after CXL.
CONCLUSIONS: CXL treatment for keratoconus led to an improvement in visual, refractive, topographic, and most corneal HOAs outcomes at the 12-month follow-up. However, these improvements were not enough to increase corneal MTF and the Strehl ratio of PSF.
MATERIALS AND METHODS: One hundred and eleven eyes of 111 consecutive keratoconus patients with 12-month follow-up after CXL were included. The changes in the visual acuity, manifest refractive errors, and corneal topographic parameters were evaluated. Sirius dual-scanning corneal tomography was used to determine the effectiveness of CXL on each patient's total corneal optical quality; preoperative and 12-month postoperative measurements were analyzed over a 4-mm stimulated pupil and were compared with regards to higher order corneal aberrations (total amount of higher order aberrations [HOAs], vertical coma, horizontal coma, vertical trefoil, oblique trefoil, and spherical aberration), vertical and horizontal modulation transfer function (MTF), and Strehl ratio of point spread function (PSF).
RESULTS: At 12 months, there was a significant improvement in mean uncorrected visual acuity (UCVA) (P < 0.001), best corrected visual acuity (BCVA) (P < 0.001), spherical equivalent refraction (P = 0.007), and manifest astigmatic refraction (P < 0.001). The corneal topographic measurements revealed a significant decrease in the mean simulated keratometry-1, simulated keratometry -2, and maximum keratometry compared with the baseline measurements (P < 0.001, for all). In addition, there were significant improvements in mean root mean square error values for corneal total HOA (P < 0.001), vertical coma (P < 0.001), and vertical trefoil (P = 0.008) following CXL. Mean MTF and Strehl ratio did not change after CXL (P > 0.05). The improvement in UCVA significantly correlated with the changes in vertical trefoil (r = -0.191, P = 0.044), and the improvement in BCVA and the changes in manifest astigmatic correction were also significantly correlated (r = -0.247, P = 0.009) 12 months after CXL.
CONCLUSIONS: CXL treatment for keratoconus led to an improvement in visual, refractive, topographic, and most corneal HOAs outcomes at the 12-month follow-up. However, these improvements were not enough to increase corneal MTF and the Strehl ratio of PSF.