m+Medelevator.RU
← Поиск публикаций
Biomedical physics & engineering express · 2026

Local artificial body for radiation analysis and testing (LABRAT®): additive manufacturing and dosimetric measurements of a heterogeneous mouse model phantom for pre-clinical radiation research.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tatu-Qassim Shalaine S, Cabahug John Paul C, Padaca Jose Bernardo L, Ballesteros Laureen Ida M, Ante Ulysses B, Geraldo Earl John T, Sarmiento Vladimir M, Garcia Carlos Emmanuel P, Guevara Eugene P, Marzon Jan Risty L, Manuel Mark Christian E, Feliciano Chitho P

Аннотация

Purpose. This study presents a novel method for fabricating a heterogeneous, tissue-equivalent mouse phantom model using additive manufacturing, together with dosimetric verification for applications in dosimetry for pre-clinical radiation research.Methods. Local Artificial Body for Radiation Analysis and Testing (LABRAT®) mouse phantoms were developed based on the Digimouse model. After 3D rendering, a mold-and-assemble method of additive manufacturing was done using 1:1.3 polyurethane-resin material for lung tissue, 1:1 resin-hardener mixture for soft tissue, and resin with 30% hydroxyapatite for bone. Three types of phantoms were developed: LABRAT A (full mouse), LABRAT B (with ionization chamber provision), and LABRAT C (with axial slices along the head, upper lung, lower lung, abdomen, and spine for film dosimetry). Ionization chamber measurements were performed on LABRAT B under total-body irradiation (TBI) (0.5-2.0 Gy) using 130 kVp, 5.0 mA x-rays at a 23 cm source-to-phantom distance on top of a 5 cm PMMA slab. Film calibration and 2.5 Gy TBI were also conducted on LABRAT C to obtain axial dose maps. Computed tomography (CT) images were obtained, and CT numbers of the phantoms were extracted using Slicer 5.4.0.Results. The fabrication method produced identical LABRAT®phantoms suitable for pre-clinical dosimetry. In the open field plan, the measured dose for the LABRAT B phantom inside the acrylic mouse restrainer was observed to agree by up to ±2.6% of the prescribed dose. Film images revealed the corresponding dose maps in each axial slice, which show gradients corresponding to doses of 0 to 3 Gy. Mean CT numbers were -621 ± 119 HU (lung), 70 ± 40 HU (soft tissue), and 430 ± 138 HU (bone).Conclusion. A heterogeneous mouse phantom was successfully developed and validated for dose verification in pre-clinical irradiation. LABRAT®materials demonstrated appropriate anatomical and radiological equivalence, with accurate dosimetric performance and good geometric agreement with the Digimouse model.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты