m+Medelevator.RU
← Поиск публикаций
Clinica chimica acta; international journal of clinical chemistry · 1993

Evaluation of thyroid function in patients with thyroid hormone autoantibodies.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sakata S, Komaki T, Ogawa T, Takuno H, Matsui I, Sarui H, Kojima N, Takamatsu J, Miura K

Аннотация

Serum free thyroxine (FT4) levels were measured in patients with Hashimoto's thyroiditis and Graves' disease who were seropositive for thyroid hormone autoantibodies. The methods used were equilibrium dialysis/radioimmunoassay (FT4 by equilibrium dialysis, Nichols Institute) and FT4 analog radioimmunoassay (Amerlex MFT4) before and after treatment of sera with 12.5% polyethylene glycol (PEG). Furthermore, FT4 measurement in the PEG-treated sera was done using two other analog radioimmunoassays (DPC FT4 Kit and N-FT4 Corning). Serum thyrotropin (TSH) concentration before and after i.v. infusion of thyrotropin releasing hormone (TRH) was measured in five cases of Hashimoto's thyroiditis and four cases of Graves' disease with thyroid hormone autoantibodies. Although FT4 determination by analog tracer radioimmunoassays showed unusually high values for the hormone, results obtained by an equilibrium dialysis/radioimmunoassay method showed compatible values with basal TSH. Furthermore, FT4 concentrations measured with Amerlex MFT4 after treatment of sera with 12.5% PEG, correlated well with the values obtained by equilibrium dialysis/radioimmunoassay (r = 0.98, P < 0.001). Similar results were obtained with two other analog FT4 radioimmunoassays after treatment of sera with PEG. These results indicate that real FT4 values in patients with thyroid hormone autoantibodies are compatible with basal TSH concentrations. The presence of thyroid hormone autoantibodies per se does not affect the control mechanism of the hypothalamo-pituitary-thyroid axis. It was concluded that measurement of basal TSH as well as FT4 values by either equilibrium dialysis/radioimmunoassay or analog radioimmunoassays after PEG treatment provides clinicians with valid information for assessment of the precise status of thyroid function in patients with thyroid hormone autoantibodies.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты