MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ases.70234

Медицинская библиотека · Asian journal of endoscopic surgery · 2026

Renal Pelvic Hematoma Following Robot-Assisted Pyeloplasty: Two Case Reports.

Kobayashi Saki, Sasaki Yutaro, Kadoriku Fumiya, Daizumoto Kei, Tomida Ryotaro, Kusuhara Yoshito, Yamaguchi Kunihisa, Fukawa Tomoya, Yamamoto Yasuyo, Furukawa Junya

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Renal pelvic hematoma is an uncommon but important complication after robot-assisted pyeloplasty (RAP), with few reports in the literature. Here, we report two cases of renal pelvic hematoma following RAP: A 9-year-old girl (Case 1) and a 25-year-old man (Case 2), both diagnosed with left ureteropelvic junction obstruction. Both underwent transperitoneal Anderson-Hynes pyeloplasty using 5-0 absorbable monofilament sutures. Postoperative imaging revealed renal pelvic hematoma in each case. Both patients remained hemodynamically stable and were managed conservatively. In Case 1, the hematoma and urine were aspirated through a 6 Fr ureteral catheter, whereas in Case 2, symptoms resolved spontaneously. Follow-up imaging demonstrated preserved renal function and improvement of hydronephrosis in both cases. Renal pelvic hematoma after RAP is rare but can be managed conservatively in stable patients. Careful intraoperative hemostasis and awareness of this complication are essential to ensure favorable outcomes.

Для цитирования: Kobayashi Saki, Sasaki Yutaro, Kadoriku Fumiya, Daizumoto Kei, Tomida Ryotaro, Kusuhara Yoshito, Yamaguchi Kunihisa, Fukawa Tomoya, Yamamoto Yasuyo, Furukawa Junya. Renal Pelvic Hematoma Following Robot-Assisted Pyeloplasty: Two Case Reports.. Asian journal of endoscopic surgery. 2026. DOI: 10.1111/ases.70234.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.