MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s26144520

Медицинская библиотека · Sensors (Basel, Switzerland) · 2026

Concurrent Validity and Reliability Between Noraxon Ultium™ IMU and Vicon OMC for Lower Limb Gait Assessment Across Variable Walking Speeds.

Le Trung T, Vo Ha V, Brandon Scott C E

СтатьяПеревод пока не подготовлен

Аннотация

Background

Wearable inertial measurement units (IMoCAPs) are increasingly used in clinical gait analysis due to their portability and ability to capture data outside laboratory settings; however, validation across operating conditions is essential.

Objective

To evaluate the concurrent validity and reliability of the Noraxon Ultium™ IMU system against a Vicon optical motion capture (OMC) system for lower-limb kinematics during walking across different speeds and time intervals.

Methods

Ten healthy adults performed overground walking at slow, normal, and fast self-selected speeds. Kinematics were recorded simultaneously using both systems. Discrete variables (Max, Min, ROM) were analyzed using three-factor repeated-measures ANOVA (Device × Speed × Time, p < 0.05). Agreement was assessed using Bland-Altman analysis, RMSE, and ICC (3,1), and waveform differences were evaluated using Statistical Parametric Mapping (SPM).

Results

Time effects were minimal across all planes. Sagittal-plane kinematics showed strong agreement, with small biases (<3°), low RMSE (≤2.5°), and moderate reliability (ICC = 0.65-0.74). Both systems detected increased hip and knee motion with speed, although Device × Speed interactions indicated greater IMoCAP underestimation at higher speeds. Frontal-plane agreement was poor to moderate (RMSE: 1-3°, ICC: 0.42-0.74). Transverse-plane kinematics demonstrated the largest discrepancies (RMSE up to 6-7°, ICC: 0.17-0.26), particularly for hip rotation. SPM revealed significant waveform differences across all planes.

Conclusions

The Noraxon Ultium™ IMU provides valid sagittal-plane gait assessment, moderate frontal-plane agreement, and limited reliability for transverse-plane kinematics, requiring cautious interpretation at higher speeds.

Для цитирования: Le Trung T, Vo Ha V, Brandon Scott C E. Concurrent Validity and Reliability Between Noraxon Ultium™ IMU and Vicon OMC for Lower Limb Gait Assessment Across Variable Walking Speeds.. Sensors (Basel, Switzerland). 2026. DOI: 10.3390/s26144520.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.