MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/icl.0000000000000580

Медицинская библиотека · Eye & contact lens · 2019

Influence of Corneal Topographic Parameters in the Decentration of Orthokeratology.

Gu Tianpu, Gong Boteng, Lu Daqian, Lin Weiping, Li Na, He Qing, Wei Ruihua

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate the lens decentration (LD) of orthokeratology (ortho-k) and the association between pretreatment corneal topographic parameters and LD of the ortho-k.

METHODS

Fifty right eyes of 50 myopes wearing ortho-k lenses were included in the prospective study. Corneal topography was conducted pretreatment to get topographic corneal parameters, including flat-K (K1); steep-K (K2); corneal astigmatism (CA), CA at 0 to 3 mm (3 mm-CA), 3 to 5 mm (5 mm-CA), 5 to 7 mm (7 mm-CA); surface asymmetry index (SAI); surface regularity index; the curvature of best-fit sphere; the diameter of cornea (DC); the distance from the corneal center to the corneal vertex (CCCV); flat eccentricity (E1), steep eccentricity (E2), and E1/E2 (E ratio); and the corneal curvature differences between the nasal and temporal quadrants at 0 to 3 mm (3 mm-Knt), and the corneal curvature differences between the superior and inferior quadrants at 0 to 3 mm (3 mm-Ksi), 5 mm-Knt (at 3-5 mm), 5 mm-Ksi (at 3-5 mm), 7 mm-Knt (at 5-7 mm), and 7 mm-Ksi (at 5-7 mm). The relationship between these cornea topographic parameters and LD of the ortho-k was tested using stepwise multiple linear regression models.

RESULTS

The mean magnitude of LD was 0.51±0.23 mm (0.06-1.03 mm). According to the stepwise analysis, 4 factors were associated with the overall LD (P<0.01): SAI (β=0.252), CCCV (β=0.539), 5 mm-CA (β=-0.268), and 3 mm-Ksi (β=-0.374); 5 factors were associated with the horizontal LD (P<0.01): DC (β=0.205), CCCV (β=0.881), 3 mm-CA (β=-0.217), 5 mm-Knt (β=0.15), and 3 mm-Ksi (β=-0.18); and 3 factors were associated with the vertical LD (P<0.01): SAI (β=0.542), 5 mm-CA (β=-0.188), and 3 mm-Ksi (β=-0.213).

CONCLUSION

Lens decentration is most common, but in most cases, the amount of LD is moderate and acceptable. The magnitude of LD can be predetermined by topographic corneal parameters. Surface asymmetry index, CCCV, 5 mm-Knt, and 3 mm-Ksi may be more preferable parameters in terms of the assessment of LD of ortho-k.

Для цитирования: Gu Tianpu, Gong Boteng, Lu Daqian, Lin Weiping, Li Na, He Qing, Wei Ruihua. Influence of Corneal Topographic Parameters in the Decentration of Orthokeratology.. Eye & contact lens. 2019. DOI: 10.1097/icl.0000000000000580.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.