Thoracic aortic endograft explant: a single-center experience.
Аннотация
OBJECTIVES
We report our experience following thoracic aortic endovascular repair (TEVAR) explant.
METHODS
A total of 500 TEVARs were performed from 1999 to 2009, with 4 requiring explant. Chart review was performed to identify the indications of explant, operative technique, and perioperative morbidity and mortality.
RESULTS
Indications of graft removal included device maldeployment, type I endoleak, aortoenteric fistula, and retrograde type A dissection necessitating aortic root replacement. Reconstruction was achieved with aortic homograft, Dacron, or explant of the proximal component with incorporation of the distal stent into the suture line. Mean follow-up was 13 months (0-50 months). Paraplegia and perioperative death occurred in 1 patient who underwent intraoperative conversion to open repair. There were no other major complications, and graft removal was achieved in all patients.
CONCLUSIONS
Although rare, familiarity with TEVAR explant is imperative as it is increasingly performed for broader indications. Our limited data suggest that explant can be performed successfully albeit with morbidity.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.