Multicenter validation of a cholangioscopy artificial intelligence system for the evaluation of biliary tract disease.

Marya Neil B, Powers Patrick D, AbiMansour Jad P, Marcello Matthew, Thiruvengadam Nikhil R, Nasser-Ghodsi Navine, Rau Prashanth, Zivny Jaroslav, Mehta Savant, Marshall Christopher, Leonor Paul, Che Kendrick, Abu Dayyeh Barham, Storm Andrew C, Petersen Bret T, Law Ryan, Martin John A, Vargas Eric J, Chandrasekhara Vinay

СтатьяВалидационное исследованиеМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Clinicians struggle to accurately classify biliary strictures as benign or malignant. Current endoscopic retrograde cholangiopancreatography (ERCP)-based sampling modalities including brush cytology and forceps biopsy have poor sensitivity for pathologic confirmation of malignancy. Cholangioscopy allows for direct visualization and sampling of biliary pathology; however, this technology is also associated with inaccurate classification of biliary disease. Previously, an artificial intelligence (AI) system that analyzes cholangioscopy footage was found to be more accurate in diagnosing biliary malignancy than ERCP sampling techniques. The aim of this study was to validate this AI system on a new series of examinations.

METHOD: Three academic centers collected all available unedited cholangioscopy recordings. The videos were processed by the cholangioscopy AI system. After analyzing videos, the AI system provided predictions as to whether malignancy was present. AI performance in classifying strictures was compared with the performance of brush cytology and forceps biopsy.

RESULTS

112 cholangioscopy examinations (containing 4 817 081 images) were generated from 99 patients. Of those examinations, 61 (54.5%) were for investigation of biliary strictures (31 [50.8%] benign, 30 [49.2%] malignant). For the correct classification of strictures, the AI system was 80.0% sensitive and 90.3% specific. It was also significantly more accurate for stricture classification (85.2%) than brush cytology (52.5%; P<0.001), forceps biopsy (68.2%; P=0.04), and the combination of brush cytology and forceps biopsy (66.7%; P=0.02).

CONCLUSION

A previously developed cholangioscopy AI system was found to continually outperform standard ERCP sampling modalities for accurate identification of malignancy, without additional retraining, in a multicenter validation cohort.

Для цитирования: Marya Neil B, Powers Patrick D, AbiMansour Jad P, Marcello Matthew, Thiruvengadam Nikhil R, Nasser-Ghodsi Navine, Rau Prashanth, Zivny Jaroslav, Mehta Savant, Marshall Christopher, Leonor Paul, Che Kendrick, Abu Dayyeh Barham, Storm Andrew C, Petersen Bret T, Law Ryan, Martin John A, Vargas Eric J, Chandrasekhara Vinay. Multicenter validation of a cholangioscopy artificial intelligence system for the evaluation of biliary tract disease.. Endoscopy. 2025. DOI: 10.1055/a-2650-0789.