Alparslan Burcu, Nas Omer Fatih, Eritmen Ulku Turpcu, Duran Selcen, Ozkaya Guven, Hakyemez Bahattin

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this study was to investigate the effect of stent cell geometry on midterm results of carotid artery stenting (CAS).

MATERIALS AND METHOD: One hundred fifty-five patients underwent CAS between February 2010 and December 2012. Ninety-one open- and 84 closed-cell stents were used in this non-randomized, retrospective study. Periprocedural complications were defined as the ones happened during the procedure or within 30 days afterwards. Starting from the 6th month after the procedure, in-stent restenosis was detected with multidetector computed tomography angiography and classified into four groups from focal restenosis to occlusion.

RESULTS

Eleven complications were encountered in the periprocedural period (four on the open- and seven on the closed-cell group). Total complication rate was 6.3% (11/175). No significant difference was detected in terms of periprocedural complications between two groups (p = 0.643). There was statistically significant difference between stent design groups in regard to radiological findings (p = 0.002). Sixteen of open-cell stents and three of closed-cell stents had focal restenosis. One closed-cell stent had diffuse proliferative restenosis and one open-cell stent had total occlusion.

CONCLUSION

In-stent restenosis was more common in open-cell stent group, which have larger free cell area than closed-cell stents. Although our radiologic findings promote us to use closed-cell design if 'possible', no difference was detected in terms of clinical outcomes.

Для цитирования: Alparslan Burcu, Nas Omer Fatih, Eritmen Ulku Turpcu, Duran Selcen, Ozkaya Guven, Hakyemez Bahattin. The Effect of Stent Cell Geometry on Carotid Stenting Outcomes.. Cardiovascular and interventional radiology. 2015. DOI: 10.1007/s00270-015-1211-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.