m+Medelevator.RU
← Поиск публикаций
Circulation. Cardiovascular imaging · 2024

Boys With Duchenne Muscular Dystrophy Have Diastolic Dysfunction Based on CMR.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Starnes Joseph R, Weiner Jeffrey G, George-Durrett Kristen, Crum Kimberly, Henderson Christopher C, Campbell M Jay, Gambetta Katheryn, Hor Kan N, Husain Nazia, Li Jennifer S, Raucci Frank J, Soriano Brian D, Spurney Christopher F, Markham Larry W, Soslow Jonathan H

Аннотация

BACKGROUND: Cardiomyopathy is the leading cause of death in boys with Duchenne muscular dystrophy (DMD). While cardiac magnetic resonance (CMR) is routinely used to assess fibrosis and left ventricular (LV) ejection fraction, CMR measures of LV filling and ejection in DMD have not been reported.

METHODS: Patients with DMD (n=179) and healthy controls (n=96) were prospectively enrolled and underwent CMR. The DMD cohort was followed clinically at multiple institutions, and clinical data were recorded. Standard volumes and functions were calculated, and LV filling and ejection curves were measured from baseline CMR. Multivariable linear regressions were used to compare ventricular filling and ejection measures between groups, adjusting for baseline differences. Cox regressions were used to evaluate the relationship between diastolic function measures and mortality in the DMD cohort.

RESULTS: Patients with DMD had significantly smaller stature and ventricular volumes than healthy control patients (P<0.001). They had lower baseline LV ejection fraction (P<0.001), though most had normal systolic function. When adjusted for age, sex, heart rate, body surface area, and LV end-diastolic volume, patients with DMD had slower peak filling rates (P<0.001) and peak ejection rates (P<0.001), as well as slower time to peak ventricular ejection rate (P=0.011). When adjusted for heart rate, a lower peak ventricular ejection rate (P=0.007) and peak filling rate (P=0.033), normalized to LV end-diastolic volume, were associated with mortality in patients with DMD.

CONCLUSIONS: Patients with DMD have significantly different baseline CMR filling and ejection indices compared with controls. Some filling indices are associated with mortality and may be useful prognostic measures. Further research is needed in larger cohorts to determine the prognostic value of these differences.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты