MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/asj/sjae228

Медицинская библиотека · Aesthetic surgery journal · 2025

Microfocused Ultrasound With Visualization (MFU-V) Effectiveness and Safety: A Systematic Review and Meta-Analysis.

Amiri Mojgan, Ajasllari Guardmond, Llane Adea, Casabona Gabriela, Pavicic Tatjana, Sevi Julia, Spada Julieta, Vachiramon Vasanop, Vasconcelos Rossana, Tuck Wah Siew, Muka Taulant, Fabi Sabrina Guillen

СтатьяСистематический обзорМетаанализПеревод пока не подготовлен

Аннотация

Microfocused ultrasound with visualization (MFU-V) is an advanced, noninvasive cosmetic procedure widely performed for skin lifting and tightening. We performed a systematic review and meta-analysis to evaluate the aesthetic effectiveness, patient satisfaction, skin quality, and safety profile of MFU-V treatment. A comprehensive search of 5 bibliographic databases up to 2023 was conducted. Pooled effect estimates with random effects models and corresponding 95% confidence intervals were calculated. Out of 4019 references, 42 studies were included. Meta-analysis showed 89% of patients (95% CI: 81%-94%; I2: 63%, n = 411) demonstrated some degree of global aesthetic improvement, as assessed by investigators. Similarly, 84% of patients (95% CI: 73%-91%; I2: 64%, n = 312) reported improvement following treatment. Satisfaction of any level was reported by 84% of patients (95% CI: 61%-94%; I²: 52%, n = 326), and 62% (95% CI: 37%-82%; I²: 3%, n = 172) when "neutral" as a response option was provided for patients. Skin quality (eg, wrinkles, texture) also improved. Patients reported a pooled mean pain score of 4.85 (95% CI: 4.35, 5.35; I2: 97%, n = 785), indicating moderate pain. Common adverse events included erythema, edema, swelling, bruising, and tenderness, all of which were generally mild to moderate in severity. Overall, our analysis demonstrated a notable increase in global aesthetic improvement and patient satisfaction following MFU-V treatment, accompanied by moderate pain and a generally favorable safety profile. However, the potential misclassification of neutral responses as positive may result in an overestimation of the treatment's efficacy. These findings highlight the need for well-designed trials to further explore MFU-V's clinical applications.

Для цитирования: Amiri Mojgan, Ajasllari Guardmond, Llane Adea, Casabona Gabriela, Pavicic Tatjana, Sevi Julia, Spada Julieta, Vachiramon Vasanop, Vasconcelos Rossana, Tuck Wah Siew, Muka Taulant, Fabi Sabrina Guillen. Microfocused Ultrasound With Visualization (MFU-V) Effectiveness and Safety: A Systematic Review and Meta-Analysis.. Aesthetic surgery journal. 2025. DOI: 10.1093/asj/sjae228.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.