MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ophtha.2016.02.008

Медицинская библиотека · Ophthalmology · 2016

In Vivo 3-Dimensional Strain Mapping of the Optic Nerve Head Following Intraocular Pressure Lowering by Trabeculectomy.

Girard Michaël J A, Beotra Meghna R, Chin Khai Sing, Sandhu Amanjeet, Clemo Monica, Nikita Eleni, Kamal Deborah S, Papadopoulos Maria, Mari Jean Martial, Aung Tin, Strouthidis Nicholas G

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To map the 3-dimensional (3D) strain of the optic nerve head (ONH) in vivo after intraocular pressure (IOP) lowering by trabeculectomy (TE) and to establish associations between ONH strain and retinal sensitivity.

DESIGN

Observational case series.

PARTICIPANTS

Nine patients with primary open-angle glaucoma (POAG) and 3 normal controls.

METHODS

The ONHs of 9 subjects with POAG (pre-TE IOP: 25.3±13.9 mmHg; post-TE IOP: 11.8±8.6 mmHg) were imaged (1 eye per subject) using optical coherence tomography (OCT) (Heidelberg Spectralis, Heidelberg Engineering GmbH, Heidelberg, Germany) before (<21 days) and after (<50 days) TE. The imaging protocol was repeated for 3 controls in whom IOP was not altered. In each post-TE OCT volume, 4 tissues were manually segmented (prelamina, choroid, sclera, and lamina cribrosa [LC]). For each ONH, a 3D tracking algorithm was applied to both post- and pre-TE OCT volumes to extract IOP-induced 3D displacements at segmented nodes. Displacements were filtered, smoothed, and processed to extract 3D strain relief (the amount of tissue deformation relieved after TE). Strain relief was compared with measures of retinal sensitivity from visual field testing.

MAIN OUTCOME MEASURES: Three-dimensional ONH displacements and strain relief.

RESULTS

On average, strain relief (averaged or effective component) in the glaucoma ONHs (8.6%) due to TE was higher than that measured in the normal controls (1.07%). We found no associations between the magnitude of IOP decrease and the LC strain relief (P > 0.05), suggesting biomechanical variability across subjects. The LC displaced posteriorly, anteriorly, or not at all. Furthermore, we found linear associations between retinal sensitivity and LC effective strain relief (P < 0.001; high strain relief associated with low retinal sensitivity).

CONCLUSIONS

We demonstrate that ONH displacements and strains can be measured in vivo and that TE can relieve ONH strains. Our data suggest a wide variability in ONH biomechanics in the subjects examined in this study. We further demonstrate associations between LC effective strain relief and retinal sensitivity.

Для цитирования: Girard Michaël J A, Beotra Meghna R, Chin Khai Sing, Sandhu Amanjeet, Clemo Monica, Nikita Eleni, Kamal Deborah S, Papadopoulos Maria, Mari Jean Martial, Aung Tin, Strouthidis Nicholas G. In Vivo 3-Dimensional Strain Mapping of the Optic Nerve Head Following Intraocular Pressure Lowering by Trabeculectomy.. Ophthalmology. 2016. DOI: 10.1016/j.ophtha.2016.02.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.