Heparin-surface-modified intraocular lenses in pediatric cataract surgery: prospective randomized study.

Basti S, Aasuri M K, Reddy M K, Preetam P, Reddy S, Gupta S, Naduvilath T J

Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the performance of heparin-surface-modified (HSM) intraocular lenses (IOLs) in pediatric eyes after cataract surgery.

SETTING

L.V. Prasad Eye Institute, Hyderabad, India.

METHODS

This prospective, randomized, double-masked, controlled clinical trial comprised 90 children aged 2 to 14 years with cataract. The patients were consecutively randomized to receive an HSM (Group 1) or an unmodified (Group 2) poly(methyl methacrylate) (PMMA) IOL. Extracapsular cataract extraction (ECCE) with IOL implantation was performed in children 8 years and older and ECCE with primary posterior capsulotomy, anterior vitrectomy, and IOL implantation in children younger than 8 years. Outcome parameters were inflammatory cell deposits on the IOL surface, posterior synechias, and anterior chamber reaction.

RESULTS

Follow-up data were available for 73, 70, 60, and 68 patients at 1 week, 1 month, 3 months, and 6 months, respectively. Significantly fewer cell deposits were noted in Group 1 at 1, 3, and 6 months (P < .001). Synechia formation and anterior chamber reaction were comparable in the 2 groups.

CONCLUSION

The lower incidence of inflammatory cell deposit formation in eyes with HSM PMMA IOLs indicates that these IOLs have greater bicompatibility than unmodified IOLs in pediatric cataract surgery.

Для цитирования: Basti S, Aasuri M K, Reddy M K, Preetam P, Reddy S, Gupta S, Naduvilath T J. Heparin-surface-modified intraocular lenses in pediatric cataract surgery: prospective randomized study.. Journal of cataract and refractive surgery. 1999. DOI: 10.1016/s0886-3350(99)00039-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.