One Size Does Not Fit All: Micro-, Meso-, and Macrobleeds in Cerebral Amyloid Angiopathy.

Koemans Emma A, van Harten Thijs W, Voigt Sabine, Rasing Ingeborg, van Zwet Erik W, Terwindt Gisela M, van Osch Matthias J P, van Walderveen Marianne A A, Wermer Marieke J H

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

MRI rating criteria for small vessel disease markers include definitions for microbleeds and macrobleeds but do not account for small (<10 mm) hemorrhages with a cystic cavity and/or irregular shape. Such hemorrhages, however, are often present in patients with cerebral amyloid angiopathy (CAA). In this study, we aimed to investigate the frequency, diameter, and volume distribution of these hemorrhages (which we called mesobleeds) in patients with CAA.

METHODS

We selected participants with Dutch-type hereditary CAA (D-CAA) and sporadic CAA (sCAA) and scored microbleeds, mesobleeds, and macrobleeds on 3T susceptibility-weighted images MRI. Hemorrhage diameter and volume were calculated in a subset of participants using a semi-automatic tool; their distribution was evaluated on a logarithmic scale.

RESULTS

We included 25 participants with D-CAA (mean age 56 years) and 25 with sCAA (mean age 73 years). In total, 11,007 microbleeds, 602 mesobleeds, and 195 macrobleeds were observed. Eighty-two percent of participants had ≥1 mesobleed. Hemorrhage diameter and volume were calculated in four participants with 272 microbleeds (median diameter 1.52 mm, volume 0.004 mL), 84 mesobleeds (median diameter 5.61 mm, volume 0.06 mL), and 37 macrobleeds (median diameter 19.58 mm, volume 1.33 mL). Mesobleed diameter and volume were larger than microbleeds (optimal cut-off 0.02 mL) but showed overlap with macrobleeds.

CONCLUSION

Hemorrhages <10 mm with an irregular shape and/or cystic cavity are frequently found in participants with CAA and have a distinct diameter and volume distribution. We propose to name these hemorrhage mesobleeds and to rate them separately from micro- and macrobleeds. Future research is necessary to investigate their pathophysiology and prognostic value.

Для цитирования: Koemans Emma A, van Harten Thijs W, Voigt Sabine, Rasing Ingeborg, van Zwet Erik W, Terwindt Gisela M, van Osch Matthias J P, van Walderveen Marianne A A, Wermer Marieke J H. One Size Does Not Fit All: Micro-, Meso-, and Macrobleeds in Cerebral Amyloid Angiopathy.. Cerebrovascular diseases (Basel, Switzerland). 2024. DOI: 10.1159/000540899.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.