m+Medelevator.RU
← Поиск публикаций
PloS one · 2026

Development and validation of a photogrammetry-based preoperative method (BREAST-E) for quantitative breast morphometric analysis and volume estimation of breast in reconstructive surgery.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

See Mee Hoong, Ng Kwan Hoong, Ong Teng Aik, Wong Lai Kuan, Lai Lee Lee, Teo Sheng Pu, Ng Jing Hui, Tneoh Jia Min, Danaee Mahmoud

Аннотация

BACKGROUND: The demand for reproducible, reliable, and cost-effective tools regarding preoperative breast surgery planning is significant in low- and middle-income countries (LMICs) due to limited advanced imaging access, insufficient standardisation, and high cost. This study developed the BREAST-E technique for accurate and standardised breast volume analysis.

METHODOLOGY: A photogrammetry method assessed four ptosis levels: (i) no-ptosis, (ii) mild, [Watterson PA, et al. Plastic and Reconstructive Surgery. 1995;95:1185-94] moderate, and (iv) severe. Key parameters included marker counts (20, 40, and 60), photo angles (10°, 20°, and 30°), and offset adjustments (-0.01, 0, and +0.01). Two-dimensional (2D) images were converted into 3D models via Photomodeler for volume estimation. Clinical validation involved 12 patients (13 breasts) undergoing mastectomy, comparing estimated breast volumes to mastectomy specimens. The primary endpoint was accuracy of volume estimation compared with mastectomy specimen volume, while secondary endpoints included reliability, agreement, and workflow feasibility.

RESULTS: The BREAST-E technique yielded promising accuracy [Pearson correlation coefficient (R) = 0.899 and mean absolute error (MAE) = 98.12 mL] and encouraging reliability (ICC = 0.995-0.996) across ptosis levels. Bland-Altman analysis indicated negligible bias, while Cronbach's alpha (reaching 0.994) demonstrated robust internal consistency. Clinical validation also implied strong performance (R = 0.789, MAE = 104.69 mL, and mean error = -27.00 mL). Consequently, no-ptosis presented the highest reliability (ICC = 0.81 and Cronbach's alpha = 0.92) with minimal bias, whereas moderate and severe ptosis levels demonstrated greater variability.

CONCLUSION: This study successfully indicated that a reproducible, accessible, and cost-effective method for analysing breast volume was accomplished through the proposed BREAST-E technique for LMICs.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты