MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rli.0000000000000023

Медицинская библиотека · Investigative radiology · 2014

Diagnostic accuracy of whole-brain computed tomographic perfusion imaging in small-volume infarctions.

Thierfelder Kolja M, von Baumgarten Louisa, Löchelt Antje C, Meinel Felix G, Armbruster Marco, Beyer Sebastian E, Patzig Maximilian, Opherk Christian, Reiser Maximilian F, Sommer Wieland H

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The aims of this study were to determine the diagnostic accuracy of whole-brain computed tomographic perfusion (WB-CTP) in small ischemic brain infarctions and to identify factors influencing the detection rate.

MATERIALS AND

METHODS

Out of a retrospective cohort of 1380 subjects who underwent initial WB-CTP because of suspected stroke, we selected all patients with a supratentorial magnetic resonance imaging-confirmed ischemic infarction with a volume of 8 mL or less. Infratentorial lesions were excluded. The study was designed as a case-control study with a ratio of cases to controls with no infarction in follow-up magnetic resonance imaging of 1:3. Two blinded readers independently evaluated 4 different computed tomographic perfusion parameter data sets per subject with respect to the presence and localization of a perfusion deficit.

RESULTS

A total of 113 subjects met the inclusion criteria for the patient group. Overall, WB-CTP reached a sensitivity of 43.4% and a specificity of 92.9%. Among these, cortical infarctions were detected in 31 (69%) of 49 cases, whereas subcortical infarctions were detected only in 18 (28%) of 64 cases (P < 0.05). Mean final infarction diameter (17.3 mm) and volume (1.9 mL) of infarctions detected on CTP were significantly larger than those of infarctions not detected (12.4 mm and 0.8 mL, respectively; P < 0.001). Time from symptom onset did not differ significantly between infarctions that were detected or those that were not (204 vs 189 minutes; P = 0.75).

CONCLUSIONS

The detection rate of WB-CTP in small infarctions highly depends on infarction localization and final size, whereas time from symptom onset does not seem to influence diagnostic accuracy.

Для цитирования: Thierfelder Kolja M, von Baumgarten Louisa, Löchelt Antje C, Meinel Felix G, Armbruster Marco, Beyer Sebastian E, Patzig Maximilian, Opherk Christian, Reiser Maximilian F, Sommer Wieland H. Diagnostic accuracy of whole-brain computed tomographic perfusion imaging in small-volume infarctions.. Investigative radiology. 2014. DOI: 10.1097/rli.0000000000000023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.