MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1542/peds.2009-3357

Медицинская библиотека · Pediatrics · 2010

Noninvasive continuous positive airway pressure in acute respiratory failure: helmet versus facial mask.

Chidini Giovanna, Calderini Edoardo, Cesana Bruno Mario, Gandini Cristiano, Prandi Edi, Pelosi Paolo

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

Noninvasive continuous positive airway pressure (nCPAP) is applied through different interfaces to treat mild acute respiratory failure (ARF) in infants. Recently a new pediatric helmet was introduced in clinical practice to deliver nCPAP. The objective of this study was to compare the feasibility of the delivery of nCPAP by the pediatric helmet with delivery by a conventional facial mask in infants with ARF.

PATIENTS AND

METHODS

We conducted a single-center physiologic, randomized, controlled study with a crossover design on 20 consecutive infants with ARF. All patients received nCPAP by helmet and facial mask in random order for 90 minutes. In infants in both trials, nCPAP treatment was preceded by periods of unassisted spontaneous breathing through a Venturi mask. The primary end point was the feasibility of nCPAP administered with the 2 interfaces (helmet and facial mask). Feasibility was evaluated by the number of trial failures defined as the occurrence of 1 of the following: intolerance to the interface; persistent air leak; gas-exchange derangement; or major adverse events. nCPAP application time, number of patients who required sedation, and the type of complications with each interface were also recorded. The secondary end point was gas-exchange improvement.

RESULTS

Feasibility of nCPAP delivery was enhanced by the helmet compared with the mask, as indicated by a lower number of trial failures (P < .001), less patient intolerance (P < .001), longer application time (P < .001), and reduced need for patient sedation (P < .001). For both delivery methods, no major patient complications occurred.

CONCLUSIONS

The results of this current study revealed that the helmet is a feasible alternative to the facial mask for delivery of nCPAP to infants with mild ARF.

Для цитирования: Chidini Giovanna, Calderini Edoardo, Cesana Bruno Mario, Gandini Cristiano, Prandi Edi, Pelosi Paolo. Noninvasive continuous positive airway pressure in acute respiratory failure: helmet versus facial mask.. Pediatrics. 2010. DOI: 10.1542/peds.2009-3357.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.