Retrospective comparative study of new slim-delivery and conventional large-cell stents for stent-in-stent methods for hilar malignant biliary obstruction.

Ishigaki Kazunaga, Fukuda Rintaro, Nakai Yousuke, Endo Go, Kurihara Kohei, Ishida Kota, Tange Shuichi, Takaoka Shinya, Tokito Yurie, Suzuki Yukari, Oyama Hiroki, Kanai Sachiko, Suzuki Tatsunori, Ito Yukiko, Sato Tatsuya, Hakuta Ryunosuke, Saito Kei, Saito Tomotaka, Hamada Tsuyoshi, Takahara Naminatsu, Mizuno Suguru, Kogure Hirofumi, Fujishiro Mitsuhiro

Многоцентровое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Endoscopic management of unresectable hilar malignant biliary obstruction (HMBO) is technically challenging, and effectiveness of stent-in-stent using large-cell, metal stents was reported. A new, large-cell stent with a 6F tapered delivery system was recently developed. The aim of this study was to compare clinical outcomes of slim-delivery and conventional large-cell stents.

METHODS

This was a multicenter retrospective comparative study of stent-in-stent methods using slim-delivery stents (Niti-S Large Cell SR Slim Delivery [LC slim-delivery]) and conventional stents (Niti-S large-cell D-type; LCD) for unresectable HMBO.

RESULTS

Eighty-three patients with HMBO were included; 31 LC slim-delivery and 52 LCD. Overall technical and clinical success rates were 100% and 90% in LC slim-delivery group and 98% and 88% in LCD group. Use of the LC slim-delivery was associated with shorter stent placement time in the multiple regression analysis, with a stent placement time of 18 and 23 min in LC slim-delivery and LCD groups, respectively. The early adverse event (AE) rate of LC slim-delivery was 10%, with no cholangitis or cholecystitis as compared to 23% in the LCD group. Recurrent biliary obstruction (RBO) rates and time to RBO were comparable between the two groups: 35% and 44%, and 8.5 and 8.0 months in LC slim-delivery and LCD groups, respectively. The major cause of RBO was tumor ingrowth (82%) in the LC slim-delivery group and sludge (43%) and ingrowth (48%) in LCD group.

CONCLUSION

Stent-in-stent methods using LC slim-delivery shortened stent placement time with low early AE rates and comparable time to RBO in patients with HMBO.

Для цитирования: Ishigaki Kazunaga, Fukuda Rintaro, Nakai Yousuke, Endo Go, Kurihara Kohei, Ishida Kota, Tange Shuichi, Takaoka Shinya, Tokito Yurie, Suzuki Yukari, Oyama Hiroki, Kanai Sachiko, Suzuki Tatsunori, Ito Yukiko, Sato Tatsuya, Hakuta Ryunosuke, Saito Kei, Saito Tomotaka, Hamada Tsuyoshi, Takahara Naminatsu, Mizuno Suguru, Kogure Hirofumi, Fujishiro Mitsuhiro. Retrospective comparative study of new slim-delivery and conventional large-cell stents for stent-in-stent methods for hilar malignant biliary obstruction.. Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society. 2023. DOI: 10.1111/den.14604.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.