MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.27116

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2020

Towards Automated Quantification of Vessel Wall Composition Using MRI.

Ziegler Magnus, Good Elin, Engvall Jan, Warntjes Marcel, de Muinck Ebo, Dyverfeldt Petter

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

MRI can be used to generate fat fraction (FF) and R2* data, which have been previously shown to characterize the plaque compositional features lipid-rich necrotic core (LRNC) and intraplaque hemorrhage (IPH) in the carotid arteries (CAs). Previously, these data were extracted from CA plaques using time-consuming manual analyses.

PURPOSE: To design and demonstrate a method for segmenting the CA and extracting data describing the composition of the vessel wall.

STUDY TYPE: Prospective.

SUBJECTS: 31 subjects from the Swedish CArdioPulmonary bioImage Study (SCAPIS).

FIELD STRENGTH/SEQUENCES: T1 -weighted (T1 W) quadruple inversion recovery, contrast-enhanced MR angiography (CE-MRA), and 4-point Dixon data were acquired at 3T.

ASSESSMENT: The vessel lumen of the CA was automatically segmented using support vector machines (SVM) with CE-MRA data, and the vessel wall region was subsequently delineated. Automatically generated segmentations were quantitatively measured and three observers visually compared the segmentations to manual segmentations performed on T1 w images. Dixon data were used to generate FF and R2* maps. Both manually and automatically generated segmentations of the CA and vessel wall were used to extract compositional data.

STATISTICAL TESTS: Two-tailed t-tests were used to examine differences between results generated using manual and automated analyses, and among different configurations of the automated method. Interobserver agreement was assessed with Fleiss' kappa.

RESULTS

Automated segmentation of the CA using SVM had a Dice score of 0.89 ± 0.02 and true-positive ratio 0.93 ± 0.03 when compared against ground truth, and median qualitative score of 4/5 when assessed visually by multiple observers. Vessel wall regions of 0.5 and 1 mm yielded compositional information similar to that gained from manual analyses. Using the 0.5 mm vessel wall region, the mean difference was 0.1 ± 2.5% considering FF and 1.1 ± 5.7[1/s] for R2*.

LEVEL OF EVIDENCE: 1.

TECHNICAL EFFICACY STAGE: 1. J. Magn. Reson. Imaging 2020;52:710-719.

Для цитирования: Ziegler Magnus, Good Elin, Engvall Jan, Warntjes Marcel, de Muinck Ebo, Dyverfeldt Petter. Towards Automated Quantification of Vessel Wall Composition Using MRI.. Journal of magnetic resonance imaging : JMRI. 2020. DOI: 10.1002/jmri.27116.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.