MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/01.cir.72.1.130

Медицинская библиотека · Circulation · 1985

Results of triple valve replacement in 91 patients: perioperative mortality and long-term follow-up.

Gersh B J, Schaff H V, Vatterott P J, Danielson G K, Orszulak T A, Piehler J M, Puga F J, Pluth J R, McGoon D C

СтатьяПеревод пока не подготовлен

Аннотация

Between 1961 and 1984, 91 patients underwent simultaneous triple valve replacement at the Mayo Clinic. Of the 273 prosthetic valves used, 77% were Starr-Edwards. Perioperative (30 day) mortality was 24% to 27% between 1962 and 1974 and 7% between 1975 and 1983 (p = .17). In patients with NYHA class IV symptoms, perioperative mortality was 44%, and in those with milder symptoms, it was 8% (p less than .0001). The median follow-up was 7.5 years (range, 6 weeks to 20 years). Cumulative survival, which was calculated taking into consideration perioperative mortality, was 64% at 1 year, 55% at 5 years, 40% at 10 years, and 25% at 15 years. Multivariate analysis identified preoperative functional class and age as predictors of late survival. Among causes of late mortality were sudden death in 32.5%, congestive heart failure in 15%, thromboembolism in 12.5%, prosthetic valve dysfunction in 7.5%, and infective endocarditis in 5%. Late complications included systemic emboli in 42% (embolic rate, 12.3 events per 100 patient-years), bleeding in 22%, myocardial infarction in 16%, and infective endocarditis in 6%. Eight patients required reoperation for prosthetic valve dysfunction, and 12 patients had permanent pacemakers. Of the 29 patients still alive, 79% are in NYHA class I or II. In summary, perioperative mortality after triple valve replacement appears to be declining; long-term survival in 30 day survivors is similar to that after single valve replacement and excellent symptomatic improvement can be obtained, although morbidity is high.

Для цитирования: Gersh B J, Schaff H V, Vatterott P J, Danielson G K, Orszulak T A, Piehler J M, Puga F J, Pluth J R, McGoon D C. Results of triple valve replacement in 91 patients: perioperative mortality and long-term follow-up.. Circulation. 1985. DOI: 10.1161/01.cir.72.1.130.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.