Evaluation of anterior segment parameters in patients with Turner syndrome using Scheimpflug imaging.

Inanc Merve, Tekin Kemal, Kurnaz Erdal, Citirik Mehmet, Altas Gülsah, Aycan Zehra

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the anterior segment parameters in patients with Turner syndrome (TS) as measured by the Pentacam HR-Scheimpflug imaging system with those of healthy control subjects.

METHODS

This cross-sectional prospective study included 35 patients with TS and 30 age-matched controls. Corneal topographic analysis was performed using the Pentacam HR-Scheimpflug imaging system (Oculus, Wetzlar, Germany). The power of the corneal astigmatism, mean keratometry (Km) values for the both front and back surfaces of the cornea, maximum keratometry (Kmax), central corneal thickness (CCT), corneal volume (CoV), white-to-white diameter (WTW), chamber volume (CaV), angle and anterior chamber depth (ACD) values were recorded.

RESULTS

The mean age of TS subjects was 17.2 ± 6.1 years; of controls, 16.4 ± 5.7 years. All participants were female. There was a significant difference in the mean values of WTW (11.3 ± 0.5 mm vs 12.0 ± 0.4 mm [P < 0.001]), CaV (148.4 ± 33.5 mm3 vs 191.9 ± 27.6 mm3 [P < 0.001]), and ACD (2.8 ± 0.3 mm vs 3.1 ± 0.2 mm [P < 0.001]) between TS versus group and the control group. The mean values of the power of the corneal astigmatism, Km values for the both front and back of the corneal surface, Kmax, CCT, CoV, and angle values were similar between groups (P > 0.05 for each one).

CONCLUSIONS

There was a reduction in CaV, ACD, and WTW measurements in TS patients compared with controls.

Для цитирования: Inanc Merve, Tekin Kemal, Kurnaz Erdal, Citirik Mehmet, Altas Gülsah, Aycan Zehra. Evaluation of anterior segment parameters in patients with Turner syndrome using Scheimpflug imaging.. Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus. 2017. DOI: 10.1016/j.jaapos.2017.10.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.