Long-Term Endothelial Cell Loss in Patients with Artisan Myopia and Artisan Toric Phakic Intraocular Lenses: 5- and 10-Year Results.

Jonker Soraya M R, Berendschot Tos T J M, Ronden Annick E, Saelens Isabelle E Y, Bauer Noël J C, Nuijts Rudy M M A

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the long-term change in endothelial cell density (ECD) after the implantation of 2 types of rigid iris-fixated phakic intraocular lenses (pIOLs) for the treatment of myopia and astigmatism.

DESIGN

Prospective, clinical cohort study.

PARTICIPANTS

A total of 507 eyes of 289 patients receiving the Artisan Myopia or Artisan Toric (Ophtec B.V., Groningen, The Netherlands) iris-fixated pIOL for the treatment of myopia or astigmatism at the University Eye Clinic Maastricht as of January 1998.

METHODS

A total of 381 myopic and 126 toric pIOLs were implanted. Five- and 10-year follow-ups were completed by 193 and 127 eyes implanted with the myopic pIOL and by 40 and 20 eyes implanted with the toric pIOL, respectively.

MAIN OUTCOME MEASURES: Chronic endothelial cell (EC) loss, percentage of eyes with a decrease of ≥25% in ECD, and percentage of eyes with an ECD <1500 cells/mm2.

RESULTS

Chronic EC loss was calculated from 6 months postoperatively to the end of follow-up and showed an annual ECD decline of 48 cells/mm2 (standard error, 3.14) and 61 cells/mm2 (standard error, 6.30) in the myopic (P < 0.001) and toric (P < 0.001) groups, respectively, resulting in a total EC loss of 16.6% and 21.5% from 6 months to 10 years postoperatively, respectively. Ten years after implantation, ECD had decreased by ≥25% in 7.9% and 6.3%, whereas ECD was <1500 cells/mm2 in 3.9% and 4.0% in the myopic and toric groups, respectively. Explantation of the pIOL occurred in 6.0% in the myopic group and 4.8% in the toric group. Risk factors for increased EC loss were a shallow anterior chamber depth (ACD) (P ≤ 0.005) and a smaller distance between the central and peripheral pIOL edge to the endothelium (P ≤ 0.005).

CONCLUSIONS

A significant linear chronic EC loss was reported after implantation with myopic or toric iris-fixated pIOLs. A smaller ACD and smaller distance between pIOL edge and endothelium were risk factors for EC loss. Modification of preoperative age-related ECD thresholds is indicated to maintain an ECD that warrants safe future combined pIOL explantation and cataract surgery.

Для цитирования: Jonker Soraya M R, Berendschot Tos T J M, Ronden Annick E, Saelens Isabelle E Y, Bauer Noël J C, Nuijts Rudy M M A. Long-Term Endothelial Cell Loss in Patients with Artisan Myopia and Artisan Toric Phakic Intraocular Lenses: 5- and 10-Year Results.. Ophthalmology. 2017. DOI: 10.1016/j.ophtha.2017.08.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.